arrow. Press the key “Modify”, the first two digits of the command start blinking. Modify as required
using the scroll keys, i.e. in the example above change “18” into “17” using the arrow up key (1).
• If necessary, press the tabulator key (2) to go to the next field to be modified, the minutes indication and
the start/stop/pressure band indication.
• Press the key “Program” to program the new command or the key “Cancel” to quit without reprogramming.
Adding a command at the end of an existing list
• Starting from the Main screen, press the key “Menu” (F1), press the arrow down key until the option
“Modify Parameters” is followed by a horizontal arrow.
• Activate the menu by pressing the tabulator key (2).
• Use the arrow down key (1) to scroll until the option “Clock Function” is followed by a horizontal arrow.
Press the tabulator key, following screen appears:
“Clock Function”
“Not Activated”
.
“Menu”
“Modify”
“Delete”
F1
F2
F3
Suppose the command to stop the compressor at 18:00 must be added to the list of Monday
• Press the tabulator key (2), following screen appears:
“Monday”
“Tuesday”
“Wednesday”
“Menu”
“Delete”
F1
F2
F3
• Scroll through the display until “Monday” is followed by a horizontal arrow. Press the tabulator key (2).
Scroll through the compressor start/stop/pressure band commands until the first empty command line is
indicated by the horizontal arrow.
• Press the key “Modify”; the first two digits start blinking. Enter “18:00 Compressor Stop” using the scroll
keys (1) to modify a field and the tabulator key (2) to jump from one field to another.
• Press the key “Program” to program the new command or the key “Cancel” to quit without reprogramming.
Adding a command between two existing commands
Suppose the command “17:00 Pressure Band 2” must be added to the following list:
• 06:00 Start Compressor
• 06:00 Pressure Band 1
• 18:00 Stop Compressor
The regulator does not allow to enter a new command which is situated before the last command in the list
timewise.
Scroll through the display until the command before which the new command must be entered is followed
by a horizontal arrow (in the example above: “18:00 Stop Compressor”) and press the key “Modify”.
Change this command to the new command (in the example above “17:00 Pressure Band 2”)
Instruction book
44
APFS998935v00
Summary of Contents for ZT-55
Page 1: ...CustomDesign Oil free Air Project 998935 Customer AIR SEP USA ZT 55 Instruction book ...
Page 2: ......
Page 13: ...General view Rear view Instruction book APFS998935v00 11 ...
Page 25: ...Typical example Drive motor M1 Instruction book APFS998935v00 23 ...
Page 57: ...4 2 Installation proposals Installation proposal ZT Pack Instruction book APFS998935v00 55 ...
Page 88: ......
Page 89: ......