3.20 Saved data menu
Control panel
Function
To call up some data saved by the regulator. These data are:
• Last shut-down data
• Last emergency stop data
Procedure
Starting from the Main screen (see
):
• Press the key “Menu” (F1).
• Press the arrow down key (1) until “Saved Data” is followed by a horizontal arrow.
• Activate the menu by pressing the tabulator key (2).
• The first option is shown “Last shutdown 1”.
• Press the tabulator key (2) to find out the date, time and other data reflecting the status of the compressor
at the last shut-down.
• If desired, scroll through the other items.
3.21 Programmable settings
Parameters
Minimum
setting
Factory
setting
Maximum
setting
Motor running time in star
sec
10
10
30
Load delay time (star-delta)
sec
10
10
30
Number of motor starts
starts/day
0
240
240
Minimum stop time
sec
20
20
99
Programmed stop time
sec
3
3
20
Power recovery time (ARAVF)
sec
15
15
3600
Instruction book
APFS998935v00
49