Minimum
setting
Factory
setting
Maximum
setting
Oil temperature (shut-down level)
˚F
104
158
176
Service warning level for DP, air filter
mbar
100
44
44
Service warning level for DP, air filter
psi
1.45
0.6
0.6
Delay at signal, DP air filter
sec
0
60
255
Service plans
Minimum
setting
Factory
setting
Maximum
setting
Service plan A (running hours)
hr
See remark
3600
See remark
Service plan B (running hours)
hr
See remark
8000
See remark
Service plan C (running hours)
hr
See remark
16000
See remark
Service plan I (running hours)
hr
See remark
2000
See remark
Remark
A number of service operations are grouped (Level A, Level B, ...). Each level stands for a number of service
operations to be carried out at the intervals programmed. Consult your Atlas Copco Service Centre.
Terminology
Term
Explanation
ARAVF
Automatic restart after voltage failure.
Compressor
element 1/2
Element 1 stands for the low-pressure compressor element; element 2 stands for the high-
pressure compressor element.
The regulator does not accept illogical settings, e.g. if the warning level is programmed at
205 ˚C, the minimum limit for the shut-down level changes into 206 ˚C. The recommended
difference between the warning level and shut-down level is 10 ˚C.
Compressor
element 1/2
Element 1 stands for the low-pressure compressor element; element 2 stands for the high-
pressure compressor element.
The regulator does not accept illogical settings, e.g. if the warning level is programmed at
401 ˚F, the minimum limit for the shut-down level changes into 402 ˚F. The recommended
difference between the warning level and shut-down level is 18 ˚F.
Required stop
period/Minimum
stop time
Once the compressor is automatically stopped, it will remain stopped for the minimum stop
time (approx. 20 seconds), whatever happens with the air net pressure. In automatic
operation, the compressor will not be stopped by the regulator until a standstill period of
at least the sum of the minimum stop time and required stop period is expected. However,
if the decrease in air net pressure should require a new start of the compressor, the
regulator will start the compressor after the minimum stop time.
Power recovery
time
Is the period within which the voltage must be restored to have an automatic restart. Is
accessible if the automatic restart is activated. To activate the automatic restart function,
consult Atlas Copco.
Unloading/
Loading pressure
The regulator does not accept illogical settings, e.g. if the unloading pressure is
programmed at 7.0 bar(e), the maximum limit for the loading pressure changes into 6.9
bar(e). The recommended minimum pressure difference between loading and unloading
is 0.6 bar.
Instruction book
APFS998935v00
51
Summary of Contents for ZT-55
Page 1: ...CustomDesign Oil free Air Project 998935 Customer AIR SEP USA ZT 55 Instruction book ...
Page 2: ......
Page 13: ...General view Rear view Instruction book APFS998935v00 11 ...
Page 25: ...Typical example Drive motor M1 Instruction book APFS998935v00 23 ...
Page 57: ...4 2 Installation proposals Installation proposal ZT Pack Instruction book APFS998935v00 55 ...
Page 88: ......
Page 89: ......