ATLAS North America Proprietary
Sea Scan ARC Scout MKII Operations Manual
1 of 1
Page: 66
Issue: 1.2.4
SCTM2-OPS
Operations Manual
The following table shows the Along Track Resolution in centimeters, from the end of the near field out to
the maximum range for each frequency.
Range(m)
300 kHz
600kHz
900kHz
1200kHz
1800kHz
3.1
5.08
4.6
7.59
5.97
6.2
10.16
8.54
6.91
9.3
15.25
11.99
10.37
8.74
10.0
15.66
12.41
10.78
9.16
15.0
18.61
15.36
13.74
12.11
18.6
30.49
20.74
17.49
15.86
14.24
25.0
34.27
24.52
21.27
19.64
18.02
35.0
40.18
30.42
27.17
25.55
45.0
46.08
36.33
33.08
31.45
50.0
49.04
39.28
36.03
80.0
66.75
57.00
53.75
100.0
78.56
68.81
140.0
102.19
92.43
150.0
108.09
200.0
137.62
250.0
167.15
300.0
196.67
12.2
Power Specifications
Power Supply:
Input Voltage
Input Power
Minimum
11.5 VDC
20 Watts (Peak)
Maximum
30 VDC
Absolute Maximum Rating
30.5 VDC
Typical Operating Power Consumption:
Input Voltage
Single Frequency Operation
Dual Frequency Operation
12V
4.0 W
6.5 W
16V
4.5 W
7.5 W
20V
5.5 W
9.8 W
24V
6.5 W
11.5 W
28V
7.5 W
13.0 W
30V
8.0 W
14.0 W
Input Voltage
Dual Frequency Idle
Sleep (Wake On LAN) Dual
Frequency
Sleep (Wake on Sync In)Dual
Frequency
12 VDC
4.3 W
3.7 W
2.6 W
16 VDC
4.0 W
4.0 W
2.4 W
20 VDC
6.0 W
4.3 W
2.5 W
24 VDC
6.3 W
4.7 W
2.7 W
28 VDC
6.9 W
5.1 W
2.9 W