REV. 01 2012
28 / 35
7.4 CALIBRATION OF B GAUGE
x
Select and press SELECTOR to entry the
B gauge calibration program (fig. 60).
x
Place the gauge to the
“
0
”
position as shown in
the figure 61.
x
Press SELECTOR to memorize the position.
x
Set the gauge head to the outer surface of the
shaft flange as shown in the figure 62.
x
Press SELECTOR to memorize the position.
x
Press STOP/ESC key to exit.
7.5 GENERAL SETTINGS
x
Select and press SELECTOR to entry the system settings (fig. 62).
x
Turn SELECTOR to highlight the item to be selected in red and press it to confirm.
x
Turn SELECTOR to make the different settings.
x
Press MENU/SAVE key to memorize the settings.
x
Press STOP/ESC key to exit the settings.
Length unit
: mm/inch
Weight unit
: gram/ounce
Weight resolution
: 1g/5g or 0.10oz/0.35oz
Approx/fine
: 1-30g or 0.1-0.3oz
Beeper
: enable or disenable
Stop by lifting the guard
: enable or disenable.
Start by lowering the guard
: enable or disenable.
Fig. 60
Fig. 61
Fig. 62
Fig. 62