Installation
Before installing, read the entire manual to ensure proper understanding of operation and that all features are being utilized. The AP-S15A can be
placed on a shelf or rack mounted in a standard 19" width rack. When rack mounted, placement within the rack is flexible, however the AP-S15A should
be within 6' of a dedicated 15A AC outlet. When rack mounting, use rack rail type screws of
10
/
32
" x 1". Always make sure the 15A outlet is properly
inspected by a certified electrician prior to connecting the AP-S15A. Make sure to inspect the equipment that will be connected to the AP-S15A to
ensure it does not exceed 15A total amperage draw.
AC Power Cord Retainer System
Connect the IEC 14 Gauge 12' (4m) power cord to a 15A 120VAC outlet to provide power to the AP-S15A by aligning the pins of the cord to the pins on
the chassis and inserting the cord. Press firmly to assure a good connection.
The AP-S15A incorporates an IEC Power Cord retainer bracket to prevent the cord from coming loose. To install the IEC power cord retainer bracket,
remove the two screws from the chassis of the AP-S15A, place the retainer bracket over the cord and insert the two screws through the bracket into
the chassis as illustrated below.