– 10 –

AP-S15LA

Owner’s Manual

AtlasIED.com

TELEPHONE: (800) 876-3333

SUPPORT@ATLASIED.COM

1601 JACK MCKAY BLVD. 

ENNIS, TEXAS 75119 U.S.A.

System

Type

 Power Conditioner & Suppressor

Load Rating

15A

Safety Listings

UL 60950-1 Standard

Front Panel

Outlets

1 Unswitched, 

Note:

 All Outlets are Surge and RF Protected

Activation Switch

Rocker with Security Cover

Indicators

AC Power ON (Blue), Surge Protect (Red), Ground (Green)

Lights

1 Pull Out Lamp with Dimmer

Rear Panel

AC Outlets

8 Outlets Total, 7 Switched & 1 Unswitched

AC Mains IEC Power Socket

15A 1800W

Circuit Breaker

15A Resettable

Technical

Max AC Mains Current 

15A AC Mains Breaker

Operating Voltage

102VAC - 132VAC

Power Consumption 

6 Watts

Min. Spike Clamping Voltage

460 VRMS @ 3,000A

Max. Spike Clamping Voltage

6kV

Max. Spike Clamping Resp. Time

1 nanosecond

Spike Clamping Voltage @ 100A

1250Vp for 20µs

Maximum Surge Current

6,500A

Energy Rating @ 2ms

200 Joules

Noise Attenuation RFI

10dB @ 10kHz / 40dB @ 100kHz / 100dB @ 10MHz

Temperature Range

5° to 35°C

Humidity Range

5% to 95% Relative Humidity

Mechanical

Color

Black

Rack Mount Requirements

1 RU, 19"

Weight (Net)

5 lbs (2.27kg)

Dimensions

19" W x 1.75" H x 5" D (483mm x 45mm x 127mm)

In The  Box

Manual

IEC Power Cord 14 Gauge 12ft (4M)

IEC Power Cord Retainer Bracket

Warranty Coverage

Warranty Period

3 Years

Summary of Contents for AP-S15LA

Page 1: ... 1 AtlasIED com TELEPHONE 800 876 3333 SUPPORT ATLASIED COM 1601 JACK MCKAY BLVD ENNIS TEXAS 75119 U S A AP S15LA AC Power Conditioner Distribution Unit ...

Page 2: ...IED COM 1601 JACK MCKAY BLVD ENNIS TEXAS 75119 U S A Table of Contents Important Safety Instructions 3 Introduction 5 Key Features and Applications 6 Front Panel Description 7 Rear Panel Description 8 Installation 9 AC Power Cord Retainer System 9 Specifications 11 Warranty 12 ...

Page 3: ...has been spilled or objects have fallen into the device the device has been exposed to rain or moisture does not operate normally or has been dropped 15 This product is equipped with a three wire grounding type plug a plug having a third grounding pin This plug will only fit into a grounding type power outlet This is a safety feature If you are unable to insert the plug into the outlet contact you...

Page 4: ...en connecting equipment Fire and or property damage may result Operate the product only with the voltage specified on the unit Fire and or electric shock may result if a higher voltage is used Do not modify kink or cut the power cord Do not place the power cord in close proximity to heaters and do not place heavy objects on the power cord including the product itself doing so may result in fire or...

Page 5: ... in that the integrator can select the power cord length that is required for the installation A removable 12 IEC power cord with a retainer bracket is supplied with the unit A shorter or longer cord can be purchased separately if needed Unstable AC Mains voltage is one of the main reasons for equipment failure The amount of energy that can be injected into the power system can be immense with vol...

Page 6: ...tection 15A Spike Suppression up to 6000V AC Fault Indicator Ground Status Indicator Removable IEC Power Cord with a Retainer Bracket Applications The AP S15LA was designed to be flexible with features that allow it to be used in a variety of applications The AP S15LA can be used solely for protection against voltage surges or for AC distribution If fuzzy video or frequent static pops occur the AC...

Page 7: ... transient voltage spikes and surges nature has a way of occasionally creating electrical forces that are beyond the capabilities of any device to absorb without some degree of damage In the rare instance that this occurs and the circuit has been damaged the Red Surge Protect LED indicator will turn Off If the Surge Protection LED in off all AC outlets will remain functional but the device will ha...

Page 8: ...wer Breaker The 15A rated breaker will open if the combined draw of all AC outlets exceeds 15A Note The breaker is designed to exceed its rating for a short period of time If the breaker is tripped the load must first be removed from the AP S15LA before pushing to reset 4 Unswitched AC Outlet The 120VAC outlet is always live when the AP S15LA power cord is plugged into an AC mains power source Not...

Page 9: ...y inspected by a certified electrician prior to connecting the AP S15LA Make sure to inspect the equipment that will be connected to the AP S15LA to ensure it does not exceed 15A total amperage draw AC Power Cord Retainer System Connect the IEC 14 Gauge 12 4m power cord to a 15A 120VAC outlet to provide power to the AP S15LA by aligning the pins of the cord to the pins on the chassis and inserting...

Page 10: ...Circuit Breaker 15A Resettable Technical Max AC Mains Current 15A AC Mains Breaker Operating Voltage 102VAC 132VAC Power Consumption 6 Watts Min Spike Clamping Voltage 460 VRMS 3 000A Max Spike Clamping Voltage 6kV Max Spike Clamping Resp Time 1 nanosecond Spike Clamping Voltage 100A 1250Vp for 20µs Maximum Surge Current 6 500A Energy Rating 2ms 200 Joules Noise Attenuation RFI 10dB 10kHz 40dB 100...

Page 11: ...S OUVRIR 15A 1800W Max AC 120V 60Hz Power Distribution Unit Model AP S15LA Voltage Protection Rating 400V L N 500V L G 400V N G Electrical Rating 12A 125V AC 60Hz 1500W Made in China ID S Caution To reduce the risk of electric shock use only in dry locations indoors Do not plug into another relocatable power tap The input plug of this power distribution unit is intended to serve as the disconnect ...

Page 12: ...d with the returned product s a written request for an estimate of repair costs before any nonwarranty work is performed In the event of replacement or upon completion of repairs return shipment will be made with the transportation charges collect EXCEPT TO THE EXTENT THAT APPLICABLE LAW PREVENTS THE LIMITATION OF CONSEQUENTIAL DAMAGES FOR PERSONAL INJURY ATLASIED SHALL NOT BE LIABLE IN TORT OR CO...

Reviews: