background image

– 4 –

AP-S15LA

Owner’s Manual

AtlasIED.com

TELEPHONE: (800) 876-3333

SUPPORT@ATLASIED.COM

1601 JACK MCKAY BLVD. 

ENNIS, TEXAS 75119 U.S.A.

 

  WARNING -  When The Device Is In Use

  

 

•  WARNING: For the terminals marked with symbol of        may be of sufficient magnitude to constitute a risk of electric shock. The external wiring  
 

connected to the terminals requires installation by an instructed person or the used of ready-made leads or cords.

•  WARNING: The apparatus shall not be exposed to dripping or splashing and that objects filled with liquids, such as vases, shall not be placed on  
 apparatus. 
•  WARNING: The mains plug is used as disconnect device, the disconnect device shall remain readily operable.
•  To prevent electric shock, do not remove the product cover as there are high voltage components inside. Refer all servicing to  
 AtlasIED. 
•  Should any of the following irregularities occur during use, immediately switch off the power, disconnect the power cord from the AC outlet and  
 

contact AtlasIED. Do not to attempt to continue operation with the product as this may cause fire or electric shock:

 

•  Smoke or strange smell coming from the unit.

 

•  If the product falls or the case is damaged.

 

•  If water or any metallic objects falls into the product.

 

•   If the power supply cord is damaged in any way.

 

•  If the unit is malfunctioning.

• 

Do not insert or drop metallic objects or flammable materials into the ventilation holes of the product's cover, as this may result in electric shock or  

 fire.
• 

Do not place any containers with liquid or metallic objects on the top of the product. If any liquid spills into the unit, fire or electric shock may result.

• 

Never operate this product or touch the power supply cord during an electrical storm, electric shock may result.

• 

Never exceed the power rating on the product when connecting equipment. Fire and/or property damage may result. 

• 

Operate the product only with the voltage specified on the unit. Fire and/or electric shock may result if a higher voltage is used. 

• 

Do not modify, kink, or cut the power cord. Do not place the power cord in close proximity to heaters and do not place heavy objects on the power  

 

cord, including the product itself, doing so may result in fire or electrical shock. 

• 

Ensure that the safety ground terminal is connected to a proper ground. Never connect the ground to a gas pipe as a catastrophic disaster may  

 result. 
• 

Be sure the installation of the product is stable, avoid slanted surfaces as the product may fall and cause injury or property damage.

 

  CAUTION - When Installing The Product

 
•   Plugging in or unplugging the power cord with wet hands may result in electric shock. 
•  Never move the unit with the power cord plugged into the wall, as damage to the power cord may result.  
•  When unplugging the cord from the wall, grasp the plug, NOT the cord. 
•  Never install this product in humid or dusty locations, nor in direct sunlight, near sources of heat, or in areas where sooty smoke or steam are  
 

present. Fire and electric shock may result.

•  Keep all sides of the unit at least 3

1

/

2

" away from objects that may obstruct air flow to prevent the unit's internal temperature rise.

 

  CAUTION - When The Product Is In Use

 
•  Never place heavy objects on the product, causing it to fall and/or break, resulting in personal injury and property damage. In addition, the product  
 

itself may fall and cause injury and property damage. 

•  Contact AtlasIED for instructions on cleaning the inside of the unit. Large accumulations of dust inside the unit may result in heat buildup and fire. 
•  Ensure that the power supply plug is securely plugged into the wall outlet. Never allow dust to accumulate on the power plug or inside the wall  
 outlet. 
•  When cleaning the unit or the unit is not to be operated for an extended period, unplug the power cord from the wall.

Summary of Contents for AP-S15LA

Page 1: ... 1 AtlasIED com TELEPHONE 800 876 3333 SUPPORT ATLASIED COM 1601 JACK MCKAY BLVD ENNIS TEXAS 75119 U S A AP S15LA AC Power Conditioner Distribution Unit ...

Page 2: ...IED COM 1601 JACK MCKAY BLVD ENNIS TEXAS 75119 U S A Table of Contents Important Safety Instructions 3 Introduction 5 Key Features and Applications 6 Front Panel Description 7 Rear Panel Description 8 Installation 9 AC Power Cord Retainer System 9 Specifications 11 Warranty 12 ...

Page 3: ...has been spilled or objects have fallen into the device the device has been exposed to rain or moisture does not operate normally or has been dropped 15 This product is equipped with a three wire grounding type plug a plug having a third grounding pin This plug will only fit into a grounding type power outlet This is a safety feature If you are unable to insert the plug into the outlet contact you...

Page 4: ...en connecting equipment Fire and or property damage may result Operate the product only with the voltage specified on the unit Fire and or electric shock may result if a higher voltage is used Do not modify kink or cut the power cord Do not place the power cord in close proximity to heaters and do not place heavy objects on the power cord including the product itself doing so may result in fire or...

Page 5: ... in that the integrator can select the power cord length that is required for the installation A removable 12 IEC power cord with a retainer bracket is supplied with the unit A shorter or longer cord can be purchased separately if needed Unstable AC Mains voltage is one of the main reasons for equipment failure The amount of energy that can be injected into the power system can be immense with vol...

Page 6: ...tection 15A Spike Suppression up to 6000V AC Fault Indicator Ground Status Indicator Removable IEC Power Cord with a Retainer Bracket Applications The AP S15LA was designed to be flexible with features that allow it to be used in a variety of applications The AP S15LA can be used solely for protection against voltage surges or for AC distribution If fuzzy video or frequent static pops occur the AC...

Page 7: ... transient voltage spikes and surges nature has a way of occasionally creating electrical forces that are beyond the capabilities of any device to absorb without some degree of damage In the rare instance that this occurs and the circuit has been damaged the Red Surge Protect LED indicator will turn Off If the Surge Protection LED in off all AC outlets will remain functional but the device will ha...

Page 8: ...wer Breaker The 15A rated breaker will open if the combined draw of all AC outlets exceeds 15A Note The breaker is designed to exceed its rating for a short period of time If the breaker is tripped the load must first be removed from the AP S15LA before pushing to reset 4 Unswitched AC Outlet The 120VAC outlet is always live when the AP S15LA power cord is plugged into an AC mains power source Not...

Page 9: ...y inspected by a certified electrician prior to connecting the AP S15LA Make sure to inspect the equipment that will be connected to the AP S15LA to ensure it does not exceed 15A total amperage draw AC Power Cord Retainer System Connect the IEC 14 Gauge 12 4m power cord to a 15A 120VAC outlet to provide power to the AP S15LA by aligning the pins of the cord to the pins on the chassis and inserting...

Page 10: ...Circuit Breaker 15A Resettable Technical Max AC Mains Current 15A AC Mains Breaker Operating Voltage 102VAC 132VAC Power Consumption 6 Watts Min Spike Clamping Voltage 460 VRMS 3 000A Max Spike Clamping Voltage 6kV Max Spike Clamping Resp Time 1 nanosecond Spike Clamping Voltage 100A 1250Vp for 20µs Maximum Surge Current 6 500A Energy Rating 2ms 200 Joules Noise Attenuation RFI 10dB 10kHz 40dB 100...

Page 11: ...S OUVRIR 15A 1800W Max AC 120V 60Hz Power Distribution Unit Model AP S15LA Voltage Protection Rating 400V L N 500V L G 400V N G Electrical Rating 12A 125V AC 60Hz 1500W Made in China ID S Caution To reduce the risk of electric shock use only in dry locations indoors Do not plug into another relocatable power tap The input plug of this power distribution unit is intended to serve as the disconnect ...

Page 12: ...d with the returned product s a written request for an estimate of repair costs before any nonwarranty work is performed In the event of replacement or upon completion of repairs return shipment will be made with the transportation charges collect EXCEPT TO THE EXTENT THAT APPLICABLE LAW PREVENTS THE LIMITATION OF CONSEQUENTIAL DAMAGES FOR PERSONAL INJURY ATLASIED SHALL NOT BE LIABLE IN TORT OR CO...

Reviews: