background image

 

REFRIGERATED PASS THROUGH DISPLAY CASE 

 

WCPT SERIES 

--------------------------------------------------------------------------------------------------------------------------------------------------------------------

 

-------------------------------------------------------------------------------------------------------------------------------------------------------------------- 

INSTALLATION 

 

Provide the correct counter cut-out opening (see chart below) and drop unit in. The vinyl gasket assures complete 
seating. A non-toxic silicone sealer may be used between the gasket and counter top (not required). 

 

MODEL 

CUT-OUT 

REQUIRED

 

WCPT-3 

22 1/4" X 41 3/4" 

WCPT-4 

22 1/4" X 55 1/2" 

 
 

The unit should be level for draining purposes. When installing unit in counter, it is recommended that the operator 
side of the counter be completely open for air circulation.  When this is not possible, such as in an island counter, it 
is recommended that two grill openings are provided approximately 18” x 18” of free air for intake and exhaust at 
the opposite ends of counter. Also the counter must have an opening of approximately 24” x 14” to access the 
compressor for maintenance.  Then the refrigeration components can be reached by removing six (6) screws from 
control and rear panels. 
The unit is supplied with a power cord and NEMA plug. Refer to data plate on compressor housing for the 
amperage and voltage information. Use a licensed electrician when installing power source. 
For cleaning and maintenance of inside top evaporator coil a qualified refrigeration technician is recommended. 

-------------------------------------------------------------------------------------------------------------------------------------------------------------------- 
-------------------------------------------------------------------------------------------------------------------------------------------------------------------- 

OPERATION 

 

The unit is ready to be operated as soon as it is plugged in and switched on. The unit has been pre-tested for proper 
operation from 35 to 40 degrees.  
-------------------------------------------------------------------------------------------------------------------------------------------
--------------------------------------------------------------------------------------------------------------------------------------- 

 

MAINTENANCE 

NEVER

 CLEAN THE UNIT WITH A CHLORIDE BASED PRODUCT. CHLORIDES OR IMPROPER 

CLEANING COULD SCAR, MARK AND/OR CORRODE METAL. 

DO NOT

 USE STEEL WOOL OR 

ABRASIVE PRODUCTS. TO CLEAN USE SOAPY WARM WATER, RINSE THOROUGHLY TO REMOVE 
ALL RESIDUES. CLEAN CONDENSER COIL REGULARLY. 

FAILURE TO MEET THESE

 

CONDITIONS WILL VOID WARRANTY

 

 

Reviews: