REFRIGERATED PASS THROUGH DISPLAY CASE
WCPT SERIES
--------------------------------------------------------------------------------------------------------------------------------------------------------------------
--------------------------------------------------------------------------------------------------------------------------------------------------------------------
INSTALLATION
Provide the correct counter cut-out opening (see chart below) and drop unit in. The vinyl gasket assures complete
seating. A non-toxic silicone sealer may be used between the gasket and counter top (not required).
MODEL
CUT-OUT
REQUIRED
WCPT-3
22 1/4" X 41 3/4"
WCPT-4
22 1/4" X 55 1/2"
The unit should be level for draining purposes. When installing unit in counter, it is recommended that the operator
side of the counter be completely open for air circulation. When this is not possible, such as in an island counter, it
is recommended that two grill openings are provided approximately 18” x 18” of free air for intake and exhaust at
the opposite ends of counter. Also the counter must have an opening of approximately 24” x 14” to access the
compressor for maintenance. Then the refrigeration components can be reached by removing six (6) screws from
control and rear panels.
The unit is supplied with a power cord and NEMA plug. Refer to data plate on compressor housing for the
amperage and voltage information. Use a licensed electrician when installing power source.
For cleaning and maintenance of inside top evaporator coil a qualified refrigeration technician is recommended.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------
--------------------------------------------------------------------------------------------------------------------------------------------------------------------
OPERATION
The unit is ready to be operated as soon as it is plugged in and switched on. The unit has been pre-tested for proper
operation from 35 to 40 degrees.
-------------------------------------------------------------------------------------------------------------------------------------------
---------------------------------------------------------------------------------------------------------------------------------------
MAINTENANCE
NEVER
CLEAN THE UNIT WITH A CHLORIDE BASED PRODUCT. CHLORIDES OR IMPROPER
CLEANING COULD SCAR, MARK AND/OR CORRODE METAL.
DO NOT
USE STEEL WOOL OR
ABRASIVE PRODUCTS. TO CLEAN USE SOAPY WARM WATER, RINSE THOROUGHLY TO REMOVE
ALL RESIDUES. CLEAN CONDENSER COIL REGULARLY.
FAILURE TO MEET THESE
CONDITIONS WILL VOID WARRANTY
.