Installation
40
Apex-10 / Apex-10H
7.15 Oil Filling And Bleeding
DO NOT run power unit without oil. Damage to pump may occur.
If motor gets hot or sounds peculiar, stop immediately and
recheck the electric connection, amperage and incoming voltage.
• Use the hydraulic fl uid recommended in the chapter 5.5;
• Remove the oil level plug on the oil tank and pour oil in the tank about 2
3/4 gallons;
• Raise the lift about 2 feet;
• Open the bleeder of each cylinder approximate two turns (ref. fi g. 25);
• Close the bleeders when the fl uid fl ows out;
• Lower the lift completely;
• Fill with more fl uid if necessary until the tank is full.
If the oil level plug is lost or broken, order the replacement.
The oil tank must be vented well.
7.16 Installation Of The Arms
Make sure the arm safety is adjusted properly.
Make sure to check the arm safety regularly.
• Raise the carriages to a convenient height;
• Grease the holes and all pivot pins prior to installation;
• Slide the arm into the carriage yoke (ref. fi g. 27);
• Install the arm pin into the yoke hole and arm hole (ref. fi g. 27);
• After installing the arm and the pin, place the anti-rotation gear into the
arm clevis. Make sure that the beveled gear orientation is correct. To allow
the enough room to install the gear, it is advised to pull up the arm pin
during installation (ref. fi g. 28);
• Install the arm using the bolts M10X35 (ref. fi g. 29). Do not tighten the
bolts at this moment;
Summary of Contents for APEX-10
Page 1: ......
Page 19: ...Technical Specification 19 Apex 10 Apex 10H Figure 3a Standard Version...
Page 20: ...Technical Specification 20 Apex 10 Apex 10H Figure 3b Taller Version...
Page 23: ...Technical Specification 23 Apex 10 Apex 10H Figure 6 Electrical Diagram 220V 60Hz 1PH...
Page 26: ...Safety 26 Apex 10 Apex 10H...
Page 27: ...Safety 27 Apex 10 Apex 10H...
Page 30: ...Installation 30 Apex 10 Apex 10H Figure 8a Floor Plan...
Page 61: ...Parts Catalogue 61 Apex 10 Apex 10H Parts Catalogue ED 01 2015...