Installation
24
PV-15P
• Place the anti-crushing bar on the bracket and fi x it on another bracket
using M8X40 screw and nuts;
• Use a lifting device to raise the assembled beam and install it to the
column extensions as shown. The beam has the hook on each end to aid
the installation;
• Tighten all screws and nuts for connection of the beams properly.
Figure 10 – Installation Of Overhead Beam
7.9 Installation Lock Latch And Cam Plate On Column
• Determine the proper
installation position of the
lock latch and cam plate on
power-side column and off-
side column;
• Align the Latch shaft,
spacer, return spring, lock
latch and cam plate as fi g.
11 shown, install them on
power-side and off-side;
• Tighten Screw M10X16 on
each side.
• After installation, have a check make sure it is well to use.