7.0 STARTING
WARNING
Before switching on the machine, make sure that all the connections described
in the INSTALLATION chapter have been made correctly. The following
operations involve a potential risk for the operator, given the presence of
voltage on the equipment. The Personal Protective Equipment described in the
INSTALLATION manual must be worn and work must be done with due care and
attention. Operations may only be performed by a specialised technician.
Before powering the machine, carry out the following checks:
1. check that the balancing machine touches the floor at the three support points;
2. make sure that all the parts of the balancer are correctly connected and fixed;
3. make sure that the parameters (voltage and frequency) of the mains power supply are compatible with those
indicated on the rating plate of the balancer;
4. make sure the power cable is correctly connected;
5. make sure the machine shaft and flange hole are clean.
NOTE - If the machine is not fixed to the ground, there are 2 adjustable screws inside its body, they have to be
used to optimise the machine’s balancing and stabilize it.