25
9.1.1 ET (This function is available only in the absence of the LA sonar)
Enabling the ET function, after the end of the automatic distance and diameter measurement, the wheel balancer
suggests the most likely width value for the dimensions just acquired. If necessary, change the width value by
pressing the buttons, otherwise proceed with normal balancing.
CAUTION
The ET function does not work with the adapters
If the ET function is disabled, the width value (b) must be set with the buttons. The correct
measurement is that which can be measured with the compass gauge provided.
b
b) adhesive weights:
make two successive measurements on two correction planes inside the rim.
The balancing machine automatically interprets that the correction will be made with adhesive weights and the
following appears:
For a different combination of the type or position of the weights on the rim, use the button .