34
10.5 Calibration
To calibrate the machine, proceed as follows:
▪ Fit an average size wheel with a metal rim on the shaft. Example: 6” x 15” (± 1”).
▪ Set the wheel measurements as described in paragraph
USE OF THE WHEEL BALANCER.
CAUTION
Setting incorrect dimensions would mean that the machine is not correctly calibrated,
Therefore, all subsequent measurements will be incorrect until calibration is performed
once again with the correct dimensions.
Display the SETUP menu:
1. Press
to view the CALIBRATION function.
2. Add a standard weight of 60 g (2.00 oz) to the outer side, in any position. Failing a weight of 60g (2.00oz)
press
to change the calibration weight from 40 to 100g (1.40 to 3.50oz)
3. Shift the standard weight from the outside to the inside keeping the same position.
4. Turn the wheel until the standard weight is at the top (12 o’clock).
5. End of calibration.
To cancel calibration at any time, press
Summary of Contents for PWB 50
Page 1: ...PWB 50 PWB 50 Use and maintenance instruction manual English PWB50 ...
Page 2: ......
Page 43: ...43 ...