Test Run
29
PX-16A
Test Run
1.
Fill oil adjustment
a. Turn on the power after connecting oil system correctly. Press the
Up
button,
and check the rotated direction of the motor (This is right if lift is upward,
otherwise, it is wrong direction of the motor). Shut off power and exchange the
phase connection if the direction is wrong.
b. Fill the reservoir with hydraulic oil. In consideration of power unit’s durability
and keep the equipment running in the perfect condition,
please use
Hydraulic Oil 46#.
c. Lower the platforms to the lowest position.
2.
Synchronous adjustment
a. Turn the handles of the shutoff valves to the position as
Fig. 36
(Normal
working position), press the
UP
button until the both platforms up to the
position that the high limit switch stop the lifting, at this time, press the
UP
button and the red button
(See Fig. 35)
beside the oil water separator
together to raise the lift to the highest position
Fig. 35
Red button (SB)
Left
Right
Summary of Contents for PX-16A
Page 1: ......
Page 8: ...Installation Steps 8 PX 16A 1 2 Illustration for on surface installation See Fig 4 Fig 4...
Page 10: ...Installation Steps 10 PX 16A 2 2 Illustration for flush mount installation Fig 6 Fig 6...
Page 37: ...Exploded View 37 PX 16A Control Cabinet Fig 33...
Page 38: ...Exploded View 38 PX 16A Atlas Electric Power Unit 220V 50HZ 1Phase 380V 50HZ 3 Phase Fig 34...