4.4 ELECTRIC HOOK UP
Any electric connection job must be carried out by professionally qualified
personnel.
Check to make sure the characteristics of your systems correspond to those required by the
machine.
The supply voltage (and main frequency) is given on the machine nameplate. It
cannot be changed.
Connect the machine to the generator unit
.
If the machine does not include the electric plug, the
user must set one, which must conforms to the voltage of the machine, in compliance with the
regulations in force.
T
he machine should not be started up without proper grounding.
I
t is absolutely essential that:
The current intake is adequately protected against over currents with fuses or
automatic magneto-thermic switch with rated value as shown in the table.
Power supply
Rated current
Fuse Switch
220V/230V – 3ph – 50/60Hz
25A AM
25A
380V/440V – 3ph – 50/60Hz
16A AM
16A
Open the control panel;
Switch the breaker on (fig. B/3)
Switch on the electric panel (fig. B/7) and check that the gearbox motor rotation corresponds to
the indicating arrow (fig. B/6).
If not, switch two wires in the plug.