AT-VCC-RELAY-KIT

The Atlona AT-VCC-RELAY-KIT is an accessory for the Atlona Velocity™ Control System that 

provides conversion between IP control commands and relay / sensor signals. This Velocity 

Control Converter is very compact and can be placed anywhere a device requires control and 

is not IP-capable. The VCC-RELAY-KIT is remotely powered through Power over Ethernet (PoE), 

or locally from a USB power source. The primary unit installs onto any surface via a convenient 

mounting dock. A simple “click” locks it into place for a secure, reliable installation. The control 

port module supports DIN rail installation, and features four relay outputs plus four sensor inputs. 

The inputs and outputs are both configurable for various operating modes.

1 x AT-VCC

1 x AT-VCC-RELAY

Package Contents

Operating Notes

 

• 

The AT-VCC-RELAY-KIT is PoE, to power the unit, simply plug it into a PoE compatible 

network switch. If the network switch is not PoE capable, a PoE injector 

(purchased separately)

 

or USB can be used.

• 

All devices (AT-VCC, Velocity, AT-VTP, switchers, etc) should be set to static IPs or the 

DHCP IP address reserved for each individual device.

IMPORTANT

: Velocity Gateway (AT-VGW-HW) must be set up before the AT-VCC-RELAY-

KIT is fully functional.

Summary of Contents for AT-VCC-RELAY-KIT

Page 1: ...nt mounting dock A simple click locks it into place for a secure reliable installation The control port module supports DIN rail installation and features four relay outputs plus four sensor inputs The inputs and outputs are both configurable for various operating modes 1 x AT VCC 1 x AT VCC RELAY Package Contents Operating Notes The AT VCC RELAY KIT is PoE to power the unit simply plug it into a ...

Page 2: ...nnect sensor here adjusting the jumpers to the correct mode 6 3 5mm Connector Connect the 3 5mm connector to the 3 5mm port of the VCC 7 Factory Reset Button Press and hold this button to reset all settings to the factory default Relay The relay has 4 terminals which vary in function depending on how the jumpers above the ports are set Place the jumpers as shown below this can be done to a single ...

Page 3: ...e Throw SPDT Double Pole Double Throw DPDT C C C C C C Both ports are set to Contact Closure Both ports are set to Voltage Sensor The ports are set to Contact Closure for the first two ports and Voltage Sensor for the last two 1 1 1 3 3 4 Sensor The ports can be set to sense either voltage or contact closure Contact closure will react to the change in current while voltage will react to voltage as...

Page 4: ...esource tab of https atlona com product at vcc relay kit 4 Unzip the file to the local PC 5 Double click the VHelp executable to open the program Vhelp will start discovery as soon as the program is opened 6 Double click on the VCC to determine the correct one look on the bottom of the VCC for the MAC address The PC default browser will open to the AT VCC webGUI 7 Select Network Settings to open t...

Page 5: ...the technology in the room 17 Select the button located at the top right corner of the room A new menu will open 18 Press the scan network button All Atlona devices found will appear in the unassigned list 11 Open any browser on the network and type in the IP address of Velocity 12 Log in and select the button from the top left corner and select Control 13 More options will appear Select All Rooms...

Page 6: ...al for setting up relay control Select Relay Sensor from the drop down menu Type the VCC s IP into a web browser to open the Velocity Command Converter Configuration Select Velocity Control Cable from the two options NOTE If for some reason the unit isn t syncing or the settings aren t being set they can be set up manually through the VCC webGUI Select the Relay Sensor configurations NOTE Ensure t...

Page 7: ... enable login To lock the configuration of the VCC select API lock after setting a username and password and press the Save Changes button With the API lock set no configuration changes can be made through TCP commands and must be changed through the web UI System Lock should not be used unless all configuration and routing has been set and will not need to be changed Once System Lock has been sel...

Page 8: ...ed or reset from the Advanced Settings page Select it from the home page menu Reboot Use this button to restart the unit Factory Reset Use this to set everything back to default settings This will reset the unit to DHCP which may cause the IP to change and the unit to need to be rediscovered ...

Page 9: ...s atlona com product at vcc relay kit 3 Unzip the file to the local PC 4 Double click the VHelp executable to open the program Vhelp will start discovery as soon as the program is opened 5 Once the unit is found if it is out of date an exclamation mark will display next to it Right click to open the drop down menu 6 Select Update from the drop down list A new pop up will appear 7 Press the Next bu...

Page 10: ...AT VCC RELAY KIT 10 Installation Guide Notes ...

Page 11: ...AT VCC RELAY KIT 11 Installation Guide Notes ...

Page 12: ...ttps atlona com warranty 由SKU列出於 https atlona com about us china rohs 25260 R6 2022 Atlona Inc All rights reserved Atlona and the Atlona logo are registered trademarks of Atlona Inc All other brand names and trademarks or registered trademarks are the property of their respective owners Pricing specifications and availability subject to change without notice Actual products product images and onli...

Reviews: