AT-OMNI-111 / AT-OMNI-112
31
The Virtual Matrix
Configuring Redundant Streams
OmniStream decoders have the ability to identify damaged or missing streams and will recover the image almost
instantaneously. The decoder can access the same stream from two separate multicast addresses and switch
between them, when necessary.
1. Right-click on the desired
cross connection
.
2. Select
Configure Redundancy
.
3. The
Configure Redundancy
dialog will be displayed.
4.
Select the backup mode for both video and audio from the
Video backup mode
and
Audio backup mode
drop-down lists.
5. Click the
Save
button to save the changes.
Mode
Description
Off
Backup source is disabled; join request not sent.
Join Active
The decoder sends a join request only when the
decoder decides to switch between sources.
Switch time will not exceed 5 seconds.
Join Always
The decoder always joins to the backup source.
Switch time will not exceed 0.5 seconds.