AT-OMNI-121 / AT-OMNI-122
138
Appendix
Environmental
Operating Temperat
ure
+14 to +
122 °F
-10 to +50 °C
Storage Temperature
-14 to +140 °F
-10 to +
60 °C
Operating Humidity (RH)
20% to 95%, non-condensing
Power
PoE
IEEE 802.3af
Consumption
Up to 12 W (w/o analog audio), up to 25 W (w/ analog audio)
External Power Supply (optional)
Input: 110 - 220 V AC, 50/60 Hz
Output: 48 V DC, 0.83 A
Safety
CE, FCC, cULus, RoHS, RCM
Chassis
Dimensions (H x W x D)
1.34 in
x 8.19 in x
4.41 in
34 mm x 208 mm x
112 mm
Weight
1.5 lbs / 0.7 kg
Safety
CE, RoHS, FCC
Indicators and controls
PWR
1 - LED, tricolor (red, amber, green)
HDMI
2 - LED, bicolor (red, green)
LINK
2 - LED, bicolor (red, green)
ID
1 - momentary, tact-type, backlit (blue); sends an identification broadcast message over the network to
any listening devices.
Reboot
1 - Momentary, tact-type
Connectors
HDMI
2 - Type A, 19-pin, female, locking
ETHERNET
(6)
2 - RJ45, 10/100/1000 Mbps
RS-232 / IR
1 - Euroblock, 6-pin (2 ports); RS-232 on port 1 and 2, IR on port 2 only
AUDIO
2 - Euroblock 10-pin; AUDIO 1 IN/OUT, AUDIO 2 IN/OUT; accepts balanced or unbalanced line
Power
1 - Euroblock, 2-pin
Control
CEC
Supported and triggered from control systems and OmniStream encoders
RS-232
Device control and configuration; supports baud rates from 2400 to 115200
Bidirectional pass-through from control system to network
Bidirectional TCP Proxy (RS-232 commands over IP)
IR
Pass-through from control system to network
Pass-through from network to control system
(1) UHDp60 only supports 4:2:0.
(2) Scaling and deinterlacing is not supported at 1080i.
(3) All VESA resolutions are 60 Hz.
(4) Dolby Vision requires a separate license per HDMI output. Dual-
channel decoders support up to UHDp30 with Dolby Vision content.
(5) External power supply is required when using the analog audio
interface.
(6) Maximum distance per hop 300 ft (100 m), depending upon network
configuration.
Graphics Features
Slate / Logo Insertion
PNG file format, adjustable aspect ratio (keep or stretch), horizontal/vertical size, screen position; slate
mode can be set to off, manual (image always displayed, superimposed on the source signal, and will
remain if source signal is lost), auto (image will only be displayed when source signal is lost).