AT-OMNI-521
28
IR Control
OmniStream provides IR control from either the headend / source location to the displays (downstream) or from the
viewing location to the headend (upstream). For downstream IR control, either multicast or unicast mode can be
used. However, when controlling a source from the viewing location, unicast mode should be used. Refer to
Unicast
Mode (page 22)
and
Multicast Mode (page 24)
for more information.
Follow the instructions below to configure AMS to allow IR data to be sent from the encoder to the decoder endpoint.
1.
Login to AMS. Refer to
Accessing Decoders in AMS (page 16)
, if necessary.
2.
The AMS Dashboard will be displayed.
3.
Click the icon, in the upper-left corner of the AMS Dashboard.
4. Click
Devices
>
All
and locate the desired encoder from the AMS Device List.
5. Click
SERIAL
in the menu bar.
6.
Under the
Serial Port 2
section, make sure that the
Mode
drop-down list is set
infrared
. This will be the only
option for a single-channel decoder under
Serial Port 2
.
NOTE:
IR control is only supported on the
RS-232 / IR 2
(bottom) port. The IR emitter or IR receiver
must be connected to this port. Refer to
IR Connections (page 12)
for wiring information.
Basic Operation
Downstream IR Control