8
6415B–ATARM–03-Oct-08
Application Note
6.
Bus Matrix Masters
.
7.
ECC Controller
8.
I/O Considerations
Adaptation serial resistors of 27 or 33 ohms are needed on each data line and address line to
limit the following:
• Current flowing (in order to prevent simultaneous switching noise).
• Falling and rising slope (reflection problems and spectral spreading).
• Trace ringing according to the intrinsic trace characteristics.
Table 6-1.
List of Bus Matrix Masters
Master
AT91SAM9260
AT91SAM9G20
Master 0
ARM926
™
Instruction
ARM926
™
Instruction
Master 1
ARM926 Data
ARM926 Data
Master 2
PDC
PDC
Master 3
USB Host DMA
ISI Controller
Master 4
ISI Controller
Ethernet MAC
Master 5
Ethernet MAC
USB Host DMA
Table 7-1.
ECC Controller Connections
Device
ECC Connection
AT91SAM9260
1 ECC per page
AT91SAM9G20
1 ECC per page
1 ECC per 256 bytes of data