Table 5-10
.
Symbol description for illuminance calculation.
Symbols Description
ICA
Calibrated sensor responsivity at 100lx. This is 50µA according
to the sensor datasheet
Ev Illuminance
I
Current through the sensor
U
Output voltage of the sensor circuitry that is provided to the ADC
R
Series resistor of the sensor circuitry. 4.7k
Ω
has been chosen in
this design
Ev = 100 x I / ICA
Illuminance is calculated based on the relation of the actual
current through the sensor to the calibrated value at 100lx
I = U / R
Since the ADC measures the voltage across the series resistor
of the sensor circuitry it is necessary to calculate the voltage
based on the current
U = (Ev x R x ICA) / 100
Based on the current and the illuminance the output voltage of
the sensor circuitry can be calculated
Table 5-11.
Illuminance vs. ADC input voltage.
Illuminance [lux]
ADC input [V]
Illuminance
1 0.0024 Dusk
10 0.0235 Dusk
20 0.0470 Dusk
30 0.0705 Dusk
40 0.0940 Dusk
50 0.1175 Living
room
60 0.1410 Living
room
70 0.1645 Living
room
80 0.1880 Living
room
90 0.2115 Living
room
100 0.2350
Living
room
200 0.4700
Office
lighting
300 0.7050
Office
lighting
400 0.9400
Office
lighting
500 1.1750
Office
lighting
600 1.4100
Office
lighting
700 1.6450
Office
lighting
800 1.8800
Office
lighting
900 2.1150
Office
lighting
1000 2.3500
Overcast
day