background image

P.N. 1

16072

3.5-9.5KW - Basic Only

NEW / Lotus models
Up to 6.0kW (One Phase)

Also for 2x127V (2~) for Latin America

7.0kW-9.5kW (One Phase)

Also for 127V up to 5.0kW

7.0kW-9.5kW (Two Phase)

1.  Multi-pole switch

2.  Terminal block

3.  Thermostat

4.  Microswitch

5.  Switches

6.  LED Light

7.  Heating elements

8.  Pressure switch

1.  Multi-pole switch

2.  Terminal block

3.  Thermostat

4.  Microswitch

5.  Switches

6.  LED Light

7.  Heating elements

8.  Pressure switch

New/Lotus/Basic

Instant Water Heater

Model

Recommended

Cable Size

Recommended

Fuse Rating

220V 230V 240V

Heating Setting

kW Loading

Model - 3.0 

1.0;2.0 or 3.0kW 

3.0  3.3  3.6 

2.5mm

2

 

16amps

Model - 3.5 

1.5;2.0 or 3.5kW 

3.2  3.5  3.8 

2.5/4mm

2

 

20amps

Model - 5.0 

2.0;3.0 or 5.0kW 

5.0  5.5  6.0 

4/6mm

2

 

25amps

Model - 5.5 

2.5;3.0 or 5.5kW 

5.5  6.0  6.6 

4/6mm

2

 

25-32amps

Model - 7.0 

3.0;4.0 or 7.0kW 

7.0  7.7  8.3 

6/10mm

2

 

40amps

Model - 8.0 

4.0;4.0 or 8.0kW 

7.3  8.0  8.7 

6/10mm

2

 

40amps

Model - 9.5 

4.5;5.0 or 9.5kW 

8.7  9.5  10.3 

10mm

2

 

45amps

• Operating water pressure 0.3-7 BAR (5-100 psi)  • Water pressure operating power switch

• Standard 1/2"Ø compression inlet connection  • Top-left and right cable entry  • Bottom-left water entry

UNIT DIMENSIONS:  HEIGHT 185mm   WIDTH 300mm   DEPTH 110mm

Installation Instructions

Reviews: