Not controlled combined boiler (SP)
connected with accumulation (buffer) tank
Example 16
- Hydraulic diagram:
16003
1
xxxx (not controlled boiler) + x
6
xxx (DHW+ACC) + xx
0
xx (-) + xxx
0
x (-) + xxxx
3
(MK1)
Combined boiler not controlled
by the controller with manual (wood) and automatic (pellet burner)
stoking.
The ACD 03 controller controls only the operation of the heating system (according to the tank
temperature (PF sensor)), namely one heating circuit (MK1) and DHW heating tank (boiler) (SLP).
ATMOS ACD 03 controller situated on the wall in the ATMOS SWS 18 box. Operation of the boiler
fan, boiler circuit pump, operation according to two temperatures (sensors) on the buffer tank (TV and
TS) and other boiler functions including automatic start of the burner after all wood
is burnt out is
controlled by the ATMOS A25 pellet burner.
2 - 6 bar
10 – 15 °C
65–75°C(R2)
Ts
Tv
A25
Tk
Tsv
PF
M
B
A
AF
ATMOS
ACD
MK1
MKP1
VF1
SF
WF
SLP
ARU5
10. Setting menu - Hydraulics - Hydraulic diagram