USER PROGRAM
The user program is identified by a permanently lit letter followed by a dot.
•
Access
:
Press the ‘Set’ button for 5 seconds until the letter C. appears
•
Next setting
:
Press the ‘Set’ button
•
Different value
:
Press the ‘Hot Water’ button
•
Exit program
:
Press the ‘Reset’ button
Status
display
CH
water
display
Function
Setting
88
CH flow temperature
°C
C.
0.0
CH pressure sensor is de-activated
8.8
CH water pressure
Bar
F.
88
Last malfunction (gas boiler)
G.
88
Last blocking (gas boiler)
H.
88
Last malfunction (heat pump)
J.
88
Last blocking (heat pump)
L.
88
Last warning (heat pump)
S.
00
Non standard setting
INSTALLER PROGRAM
The installer program is identified by permanently illuminated letter without a dot.
•
Access
:
Press the ‘Set’ button for 10 seconds until the letter A appears
•
Next setting
:
Press the ‘Set’ button
•
Different value
:
Press the ‘Hot Water’ button
•
Exit program
:
Press the ‘Reset’ button
•
To enter sub-menu
:
Press the ‘Hot Water’ button
Status
display
CH water
display
Description
Remarks
A
??
LL / ??
HH / ??
Ionisation flow (virtual) when appliance is
operating
Low capacity (continuous), alternating with the
virtual ionisation flow
High capacity (continuous), alternating with
the virtual ionisation flow
Adjusting O2% / CO2%
b
Sb
Submenu sensor values
Sub-menu sensor values
c
01
02
03
04
05
06
One temperature zone with WDC without
RT
One temperature zone WDC with RT
Two temperature zones, linked control:
Two temperature zones, linked control:
Two temperature zones:
Two temperature zones:
Heat pump WDC without
RT, Gas boiler WDC
without RT
Heat pump WDC with RT,
Gas boiler WDC with RT
Heat pump WDC without
RT, gas boiler WDC
without RT
Heat pump WDC without
RT, gas boiler WDC with
RT