Atmos
Heating Systems
Installation and user manual EN_FMT
10
1.5. Operation
A fan sucks the air required for the combustion through the
air feed canal (A). Because the combustion air in the
venturi sucks an under pressure, the correct amount of gas
(G) is automatically added to the combustion air.
The flammable gas/air mixture thus obtained is fed to the
burner, via a mixing chamber, to be ignited at the surface of
the burner by a ceramic glow plug. The hot combustion
gases are efficiently fed through the heat exchanger, where
they give their heat to the water. The flue gases are fed
outside, through the flue tube (F), into a flue tube exhaust
canal.
The condensation water (H
2
O) thus obtained is discharged
into the sewer.
1.6. Boiler types
Atmos 40C
High efficiency boiler for central
heating only.
The Atmos boiler is a heating unit with compact dimensions
and a very high efficiency, with versions for domestic and
small commercial use for central heating.
The type plate, which specifies the type of gas etc. to be
used, for which the unit is set, is on the left side of the unit.
The unit is fixed to the wall with the aid of a separately
delivered assembly bracket or rear cabinet.
1.7. Specific caracteristics type 40
1.7.1. Burner assy N00S020000
1.7.2. Primair heat exchanger N00S040005
1.7.3. Venturi N00S020008
1.7.4. Pump N00S110006
1.8. Conditions of delivery
Coopra Advanced Heating Technologies b.v. supplies its
products according to the general conditions of delivery for
the metal and electro technical industry. Registered with the
Clerk of the District Court at Den Haag on 19 October 1998
under no. 119/1998.