At 2013 / N
V.01.2009
51
TROUBLE-SHOOTING
Fault Cause
Remedy
The aggregat supplies little air quantity
Soiling of regulation system
Clean up, Manufacturer´s service
Compressor cannot reach the appropriate air pressure
Regulation flap valve does not open the compressor suction
Check on
Engine speed cannot be raised
Soiling of speed regulator
Clean up, Manufacturer´s service
Machine runs-up heavily
There is pressure in compressor
Low ambient temperature
Heavy oil
Check on the regulation
Heat up the machine, another oil type
Use the right oil type
Machine turns off before the demanded pressure is reached
Thermal regime
Manufacturer´s service
Machine turns off for reason of too high oil temperature
Shortage of oil
Oil filter soiled
Faulty thermostat
Soiled oil cooler
Vysoká okolní teplota
Fill up
Replace
Manufacturer´s service
Clean up the cooler
High ambient temperature
Safety valve blows off
Defective valve
Soiled separator element
Regulation does not close the compressor suction
Manufacturer´s service
Replace
Manufacturer´s service
Oil in pressure air
Clogged oil drawing off
Faulty separator element
Clean up the oil drawing off connection
Check on, aptly replacement
Suction regulator works well, but the machine supplies low quantity
of air
Suction filter spoiled
Regulation flap stays "hanging"
Leakage in regulation or in the whole system
Replace the filter element
Check on, clean up, manufacturer´s service
Check on, tighten, manufacturer´s service
Survey of faults shown serves for ground orientation of the customer in case of compressor or its parts defect occurance.
Faults leading to machine shut down, are signalized on control board display.
In case of defect occurance establish contact with the manufacturer immediately.