CLEANING THE EYEPIECE

You may need to clean the eyepiece of the riflescope from time to time in order to guarantee top per-

formance. When you receive your riflescope you should check for dust on the eyepiece of the unit.
First you will need to remove the eyepiece. To do that you will need to initially loosen the 2 set screws 

that can be found on the base. Then unscrew the eyepiece counter-clockwise to remove it.

NOTE:

 

You do not have to remove the set screws completely, they are very small and easy to mis-

place.

CAUTION:

 Use only Photographic lens cleaning tissue on these surfaces. Be careful not to scratch 

or smudge any of these surfaces. When using compressed air to blow dust away, make sure to avoid 

inverting the can while spraying. This can cause frozen propellant to exit the can, which can cause 

serious problems with the glass and phosphor screen.

WARNINGS AND CAUTIONS

•  Always remember to turn off the Aries MK6600/6650/7700/7750/8700/8750 when it is not in use. 

If you do not plan on using your aries scope for a period of more than 10 days, you should remove 

the batteries.

•  Keep lens cap/daylight filter on when not in use.
•  Avoid contact with dust, steam, and gas.
•  The Aries MK6600/6650/7700/7750/8700/8750 are not harmful to the user or the environment.
•  Do not disassemble except to clean the front lens and the eyepiece: it will void your warranty.
•  Evaluate the scopes function by looking through it in a lit environment with the daylight filter lens 

cap on. Never use in daylight without the daylight filter lens cap on. Do not surpass ten minutes of 

testing.

•  Never point the Aries MK6600/6650/7700/7750/8700/8750 at a bright light source. If the scope 

shuts off automatically after directing it at a bright light source, turn the unit off and wait 1 - 2 min-

utes before turning the unit back on.

•  Adverse atmospheric conditions such as fog, smog, or haze and a lack of ambient light (moon or 

starlight) may diminish the effective viewing distance. All technical data for this unit was compiled 

in a controlled environment.

TROUBLE SHOOTING

Q:

 Flashes, flickers, or clicking occur while operating

S:

 If it occurs within the first five minutes of inserting new batteries, it is normal and the device will 

resume normal operation soon thereafter. If it occurs for more than 10 minutes, contact your dealer 

or other authorized service representative for service instructions.

Q:

 Dark spots on screen.

S:

 These are cosmetic blemishes in the intensifier tube. They are a by-product of the process of 

manufacturing night vision tubes. They will not impede your viewing ability.

Q: Image not clear.

S:

 Adjust focus ring. If problem persists, increase viewing distance

Q:

 Fixed-pattern noise in a honeycomb shape.

S:

 Usually a cosmetic blemish characterized by a faint honeycomb-type pattern. This usually occurs 

when viewing very bright lights. Adjust the potentiometer, to reduce brightness.

Q:

 A pattern of dark thin lines which look like chicken wire.

S: Turn on illuminator, if purchased. If illuminator doesn’t brighten image, replace batteries. If 

problem persists, contact ATN for service instructions.

Summary of Contents for Aries MK 6600

Page 1: ...AMERICAN TECHNOLOGIES NETWORK CORP u s e r s g u i d e Aries MK 6600 6650 Aries MK 7700 7750 Aries MK 8700 8750...

Page 2: ...accuracies that may appear in this book 2002 ATN Corp All right reserved Master power ON OFF switch Control panel Remote control panel Battery compartment Manual focus lens 5 to infinity 100m Infra re...

Page 3: ...t filter note the pinhole in the center of the lens cap MASTER POWER SWITCH The Master ON OFF switch is to be found on top of MK6600 6650 7700 7750 8700 8750 Once the scope s master power is switched...

Page 4: ...To change the field of coverage from the IR illuminator focus the beam by turning IR illuminator lens to slightly alter the beam width RETICLE BRIGHTNESS ADJUSTMENT By pressing the SL button twice you...

Page 5: ...return to its previous settings To put your scope in the SLEEP mode any time just push the SL button and simultaneously Push SL to return to previous settings and the SMART scope will remember them Th...

Page 6: ...ront lens with the Large Allen wrench included with scope After focusing lens to desired distance re lock lens in place to insure no movement of reticle while shooting NOTE To remove the front lens to...

Page 7: ...and the right horizontal posts of the main line the target is 100 yards away If the same target fits between the 2 and the right post of the main line the target is 200 yards away The same is with th...

Page 8: ...st the diopter for optimal image clarity You may now enter the dark environment or simply shut the lights off in order to darken the room Remove the lens cap daylight filter Observe the scene and adju...

Page 9: ...e daylight filter lens cap on Never use in daylight without the daylight filter lens cap on Do not surpass ten minutes of testing Never point the Aries MK6600 6650 7700 7750 8700 8750 at a bright ligh...

Page 10: ...ogy Standard Magnification 4x Intensifier Tube US 2nd Gen MK6600 6650 US 3rd Gen MK7700 7750 US 4th Gen MK8700 8750 Detection Range 250 m MK6600 6650 300 m MK7700 7750 400 m MK8700 8750 Recognition Ra...

Page 11: ...articular purpose shall apply to the product All such implied warranties are hereby and expressly disclaimed LIMITATION OF LIABILITY ATN will not be liable for any claims actions suits proceedings cos...

Page 12: ...den Ave Suite 1B South San Francisco CA 94080 phone 800 910 2862 650 875 0130 fax 650 875 0129 European Office phone 44 0 870 0111286 fax 44 0 845 3349142 The following countries can use our toll free...

Reviews: