background image

3

to change the position of the riflescope on the weaver rail additionally follow the steps men-

tioned below:
1. Unscrew the two screws, which attach the rail to the 

mounting bracket.
2. take the rail out of the groove.
3. about-face the rail in case of necessity.
4. place the rail into another groove.
5. Fix the rail with the two screws.

NOTE:

 If the rail does not come out easily, tighten one of the removed screws into the threaded 

aperture in the middle of the fixing projection of the rail. Rotate this screw, which will in turn push 

the rail out from the groove.

conTRol

the night arrow 2 has a simple and easy to operate one-knob control and adjustment.

To turn riflescope on rotate the operation knob from position marked “0”.
To turn riflescope off rotate the operation knob to position marked “0”.

after turning scope on, you may adjust the reticle’s brightness by rotating the operation knob 

from position marked “1” to position “9”. Position “1” corresponds to the minimal brightness, 

the position “9” corresponds to the maximal brightness of reticle’s glow.

 adjustment could be easily seen if you look through the scope while adjustment.  

FocusIng

to focus your riflescope you will need to adjust the diopter. Simply turn the diopter clockwise 

until it stops. then, while looking through the diopter at a subject, slowly turn the diopter back 

counter clockwise until the grain in the image is sharp.

NOTE:

 We suggest that you focus the diopter during daylight with the cap on.

opERATIon ExTEnDIbIlITy

there is picatinny rail on the body of the scope for additional lighting, laser and other mission 

critical tools. 

IR IllumInATIon

Infra-red (Ir) Illuminators are common for night vision technology. the Ir light greatly 

enhances the performance of your night arrow 2 scope, while remaining almost totally invis-

ible to the naked eye. In  dark environment, power up the atn night arrow 2. now, find a scene 

and examine it without the Ir on then with Ir powered up. note the difference in illumination. It 

is important to remember that the Ir illuminator is simply an infra red light source, and like any 

light source it may loose its effectiveness over a great distance.
to fix the Ir illuminator to the riflescope use the picatinny raile of the scope.
the Ir illuminator control buttons are located on its side. to switch the Digital Ir illuminator  

on/off press “+” and “-” buttons simultaneously. When the IR illuminator is switched on you can 

see the green LED lit.  By pushing the buttons “+” and “-” you may adjust the IR  brightness.

Ir Brightness 

adjustment

Battery 

housing

Fixation 

Screw

Ir elevation

Ir windage

Ir Focusing

nut

Groove

rail with a  

fixing projection

Screws

mounting 

system

Summary of Contents for Night Arrow 2

Page 1: ...ul and strictly prohibited to export or attempt to export or otherwise transfer or sell any hardware or technical data or furnish any service to any foreign person whether abroad or in the United Stat...

Page 2: ...E A NON REFLECTIVE MATTE BLACK FINISH EXCEPT FOR THE OPTICAL ELEMENTS RED ON GREEN RETICLE SYSTEM WITH 1 2 MOA ADJUSTMENT AUTOMATIC BRIGHTNESS CONT ROL ABC FOR TUBE PROTEC TION ONE KNOB OPERATION ILLU...

Page 3: ...Next remove the lens cap daylight filter Finally you may want to turn the infra red IR illuminator on Notice the ability of the scope to see in total darkness with the aid of the IR illuminator OPERAT...

Page 4: ...ckwise until it stops Then while looking through the diopter at a subject slowly turn the diopter back counter clockwise until the grain in the image is sharp NOTE We suggest that you focus the diopte...

Page 5: ...The result is fast precision target acquisition WINDAGE AND ELEVATION The vertical and horizontal adjustments for the Night Arrow 2 can be achieved by turning the elevation and windage adjustment mec...

Page 6: ...llergic reactions TROUBLEsHOOTING Q Flashes flickers or clicking occur while operating S If it occurs within the first five minutes of inserting new batteries it is normal and the device will resume n...

Page 7: ...ices performed by ATN to the Customer shall not be interpreted construed or regarded either expressly or implied as being for the benefit of or creating any obligation toward any third party of legal...

Page 8: ...fice 1341 San Mateo Avenue South San Francisco CA 94080 phone 800 910 2862 650 989 5100 fax 650 875 0129 European Office The following countries can use our toll free number 00 800 9102 8620 Austria F...

Reviews: