cleAning The eyepiece

You may need to clean the eyepiece of the night Shadow from time to time in order to guaran-

tee top performance. when you receive your night Shadow you should check for dust on the 

eyepiece of the unit.
First you will need to remove the eyepiece. Unscrew the eyepiece counter-clockwise to  

remove it.

CAUTION:

 Use only photographic lens cleaning tissue on these surfaces. Be careful not to 

scratch or smudge any of them. When using compressed air to blow the dust away make sure to 

avoid inverting the can while spraying. This might cause the frozen propellant to exit the can and 

cause serious problems with the glass and phosphor screens.

wArnings And cAuTions

• Always remember to turn off the 

night Shadow when it is not in use. If you do not plan on us-

ing your device for a period of more than 10 days, you should remove the batteries. 

• Keep lens cap/daylight filter on when not in use.

• Avoid contact with dust, steam, and gas.
• The 

night Shadow  is not harmful to the user or the environment.

• Do not disassemble except to clean the front lens and the eyepiece:

 it will void your 

warranty.

• Evaluate the scopes function by looking through it in a lit environment with the daylight filter 

lens cap on. never use in daylight without the daylight filter lens cap on. Do not surpass ten 

minutes of testing.

• 

never point the night shadow at a bright light source.

 If the scope shuts off automatically 

after directing it at a bright light source, turn the unit off and wait 1 - 2 minutes before turning 

the unit back on.

• Adverse atmospheric conditions such as fog, smog, or haze and a lack of ambient light 

(moon or starlight) may diminish the effective viewing distance. all technical data for this unit 

was compiled in a controlled environment.

• If you use the rubber eyecaps for a long period of time, you may suffer skin inflammation. If 

you develop any symptoms, consult a doctor immediately.

Summary of Contents for Night Shadow

Page 1: ...BIS Department of Commerce It is unlawful and strictly prohibited to export or attempt to export or otherwise transfer or sell any hardware or technical data or furnish any service to any foreign per...

Page 2: ...lergic reactions Cau t i o n Optional Accessories Power button Infra red illuminator ON OFF switch Proximity Sensor ON OFF switch Built in infrared IR illuminator Computerized proximity sensor Diopter...

Page 3: ...FICATIONS Magnification 3x 6x with Doubler 1st Gen 5x 10x with Doubler 2 CGT HPT WPT 3 3A 3P and G4 Intensifier Tube 1 2 CGT HPT WPT 3 3A 3P and G4 Lens System 6 elements F1 1 4 90 mm Field of View 14...

Page 4: ...rs When the oculars is brought to the user s eyes the bioculars will automatically turn on When removed from the eyes the device will turn off for this feature you have to engage the proximity sensor...

Page 5: ...cular distance could be adjusted manu ally To focus the Night Shadow you will need to adjust the diopter first Simply turn the diopter clockwise until it stops Then while looking to an object slowly t...

Page 6: ...s or your 35 mm camera lens Loosen the three set screws on the camera adapter Place the camera adapter over the Night Shadow eyepiece Tighten the three set screws to fit snugly to the Night Shadow eye...

Page 7: ...ght Shadow Screw the doubler onto the back of the lens Tighten the screw on the Doubler s side screw driver is provided Screw the lens with the Doubler back into the main body USING THE DOUBLER option...

Page 8: ...eadjust the front lens focusing for maximum clarity Remember the focus range of the bioculars is 20 to infinity The unit will turn on and off automatically when you bring it to or take away from your...

Page 9: ...he batteries Keep lens cap daylight filter on when not in use Avoid contact with dust steam and gas The Night Shadow is not harmful to the user or the environment Do not disassemble except to clean th...

Page 10: ...representative for service instructions Q Dark spots on screen S These are either cosmetic blemishes in the intensifier tube or dust particles The dust parti cles can be cleaned following instruction...

Page 11: ...oducts sold and services performed by ATN to the Customer shall not be interpreted construed or regarded either expressly or implied as being for the benefit of or creating any obligation toward any t...

Page 12: ...fice 1341 San Mateo Avenue South San Francisco CA 94080 phone 800 910 2862 650 989 5100 fax 650 875 0129 European Office The following countries can use our toll free number 00 800 9102 8620 Austria F...

Reviews: