SAFETY AND MAINTENANCE MANUAL
1NO0024UK-09
69
WARNING
IF THE INDICATOR LIGHTS OF THE
CHARGER LIGHT UP, AND THE
BATTERY IS NOT CHARGED BY THE
CHARGER,
IT
MUST
BE
REINITIALIZED.
FOR
THIS,
DISCONNECT THE RED CONNECTOR
FROM THE BATTERY, WAIT FOR 1
MIN, AND CONNECT AGAIN.
1 2 3 4
8
7
6
5
R
M
CONDITION
ALARM TYPE
DESCRIPTION (ACTION)
Audible m RED flash
Battery presence
Battery disconnected or not in conformity (Verify the connection and the nominal
voltage)
Audible m YELLOW flash
Thermal sensor
(option)
The thermal sensor is disconnected during the recharge or it is out of working range
(Verify the connection of the sensor and measure the temperature of the battery)
Audible m GREEN flash
Timeout
Phase 1 or/and phase 2 have a duration in excess of the maximal allowed (Verify the
battery capacity)
Audible m RED/YELLOW flash
Battery current
Loss of output current control (Failure of the control logic)
Audible m RED/GREEN flash
Battery voltage
Loss of output voltage control (Battery disconnected or failure of the control logic)
Audible m YELLOW/GREEN
flash
Selection
An unavailable configuration has been selected (Verify the selector's position : B =
575Ah)
Audible m
RED/YELLOW/GREEN flash
Thermal
Overheating of semiconductors (Verify the fan operation)
FONCTIONNEMENT DES LEDS (ZIVAN)
For the IES version charger, the Led blinks by
flashes in RED to show a fault.
3.3. DISCHARGE BATTERY
INDICATOR AND HOURMETER
GENERALITIES
The indicator of battery discharge and time meter is situated on the
upper electrical box: this is a single indicator. This meter fulfills two
major functions:
1- The capacity of the battery is indicated by 9 LEDs (8 yellow and
one red). Below 25%, the last yellow LED blinks and at 20% of
capacity, the red LED lights up and the machine stops.
2- A LCD hourmeter is used as a time meter display.
Technical specifications and electrical connections
V v 25% :
12v 24v 36V 48V
mA current consumption:
50
35
35
25
EMC:
EN 55011 EN 50082-2
Contact-relay:
Normally open, power
12v-2A / 24v-2A / 36v-1,5A / 48v / 1A
Protection:
IP 65 on FRONT side
Temperature:
-30°C to +70°C max 95% humidity
1: Motor hour meter
input -
2: Ignition key +
3: Relay +
4: Relay -
5: Battery -
6: Motor hour meter
input +
7: B
8: B
M: Push button
R: Reset (option)
1 red led
rouge
8
yellow
leds
« LCD » hourmeter
Summary of Contents for PIAF 1000R
Page 2: ...SAFETY AND MAINTENANCE MANUAL 1NO0024UK 09 2 DISTRIBUTOR STAMP...
Page 8: ...SAFETY AND MAINTENANCE MANUAL 1NO0024UK 09 8...
Page 11: ...SAFETY AND MAINTENANCE MANUAL 1NO0024UK 09 11 Chapter I USE AND SAFETY...
Page 12: ...SAFETY AND MAINTENANCE MANUAL 1NO0024UK 09 12...
Page 16: ...SAFETY AND MAINTENANCE MANUAL 1NO0024UK 09 16...
Page 22: ...SAFETY AND MAINTENANCE MANUAL 1NO0024UK 09 22...
Page 34: ...SAFETY AND MAINTENANCE MANUAL 1NO0024UK 09 34...
Page 36: ...SAFETY AND MAINTENANCE MANUAL 1NO0024UK 09 36...
Page 37: ...SAFETY AND MAINTENANCE MANUAL 1NO0024UK 09 37 Chapter II MAINTENANCE...
Page 38: ...SAFETY AND MAINTENANCE MANUAL 1NO0024UK 09 38...
Page 77: ...SAFETY AND MAINTENANCE MANUAL 1NO0024UK 09 77 3 13 ELECTRICAL DIAGRAM Diagram ref 1EL0023 01...
Page 78: ...SAFETY AND MAINTENANCE MANUAL 1NO0024UK 09 78 NOTES...