background image

3

To change the position of the riflescope on the weaver rail 

additionally follow the steps mentioned below:
1. Unscrew the two screws, which attach the rail to the 

mounting bracket.

2. Take the rail out of the groove.
3. About-face the rail in case of necessity.
4. Place the rail into another groove.
5. Fix the rail with the two screws.

NOTE:

 If the rail does not come out easily, tighten one of the removed screws into the threaded 

aperture in the middle of the fixing projection of the rail. Rotate this screw, which will in turn push 

the rail out from the groove.

DIgITAl coNTRol

The 

ATN Trident Pro

 has a simple and easy to operate one-button control and adjustment.

To turn on: 

Press the operation button by one short push

To turn off: 

Press the operation button again by one short  push

To adjust reticle brightness:
1) After turning scope on, press and hold operation button. Brightness will grow smoothly while the 

button is kept pressed. Release the button when necessary brightness is achieved.

2) Press and hold the button second time for smooth decrease of brightness. Adjustment could be 

easily seen if you look through the scope while adjustment. 

All functions of digital control are available with remote control also.

focusINg

To focus your riflescope you will need to adjust the diopter first thing. Simply turn the diopter clock-

wise until it stops. Then, while looking through the diopter at a subject, slowly turn the diopter back 

counter clockwise until the grain in the image is sharp.

NOTE:

 We suggest that you focus the diopter during daylight with the cap on.

oPERATIoN EXTENDIbIlITy

There are three detachable Picatinny rails on the body of the 

scope for additional lighting, laser and other mission critical 

tools. The rails fix with two screws as shown on the figure.

IR IllumINATIoN

Infra-red (IR) Illuminators are common for night vision technology. The IR light greatly enhances the 

performance of your 

ATN Trident Pro

 scope, while remaining almost totally invisible to the naked 

eye. In  dark environment, power up the 

ATN Trident Pro

. Now, find a scene and examine it without 

the IR on then with IR powered up. Note the difference in illumination. It is important to remember 

that the IR illuminator is simply an infra red light source, and like any light source it may loose its 

effectiveness over a great distance.
To fix the IR illuminator to the riflescope use the picatinny raile of the scope.
The IR illuminator control buttons are located on its side. To switch the Digital IR illuminator  

on/off press “+” and “-” buttons simultaneously. When the IR illuminator is switched on you can 

see the green LED lit.  By pushing the buttons “+” and “-” you may adjust the IR  brightness.
The IR beam is focusable to change the field of coverage. To change the beam width slightly turn 

the IR lens.

Grooves

Rail with a  

fixing projection

Screws

Mounting 

system

Summary of Contents for Trident Pro2x-2

Page 1: ...ful and strictly prohibited to export or attempt to export or otherwise transfer or sell any hardware or technical data or furnish any service to any foreign person whether abroad or in the United States for which a license or writ ten approval of the U S Government is required without first obtaining the required license or written approval from the Department of the U S Government having jurisdi...

Page 2: ...age 5 Diopter Battery housing Back up iron sights Mounting system IR brightness adjustment Digital Infra Red Illuminator Battery housing Fixation screw IR elevation IR windage IR focusing Afocal 2X magnifier optional Picatinny rails Lens cap LIGHT AND COMPACT DESIGN TOP NOTCH PERFORMANCE WITH PRO ORIENTED DESIGN 2X MAGNIFICATION WITH NEW F1 1 2 LENS 50MM OPTIONAL AFOCAL 2X MAGNIFIER ALL EXTERNAL S...

Page 3: ...order to darken the room Next remove the lens cap daylight filter Finally you may want to turn the infra red IR illuminator on Notice the ability of the scope to see in total darkness with the aid of the IR illuminator OPERATING MOUNTING 1 Slightly loosen the fixing screws on the 7 8 weaver mount built into the scope 2 Place the scope on the weaver rail of the fire arm 3 Tighten the fixing screws ...

Page 4: ...opter clock wise until it stops Then while looking through the diopter at a subject slowly turn the diopter back counter clockwise until the grain in the image is sharp NOTE We suggest that you focus the diopter during daylight with the cap on Operation Extendibility There are three detachable Picatinny rails on the body of the scope for additional lighting laser and other mission critical tools T...

Page 5: ... WINDAGE AND ELEVATION The vertical and horizontal adjustments for the ATN Trident Pro can be achieved by turning the elevation and windage adjust ment mechanisms remove dust caps first Each click equals 1 2 inch at 100 yards When reaching the maximum range of rotation do not use force CLEANING THE EYEPIECE You may need to clean the eyepiece of the riflescope from time to time in order to guarante...

Page 6: ... clicking occur while operating S If it occurs within the first five minutes of inserting new batteries it is normal and the device will resume normal operation soon thereafter If it occurs for more than 10 minutes contact your dealer or other authorized service representative for service instructions Q Dark spots on screen S This may be dust on the lens please clean according to instrutions They ...

Page 7: ... particular purpose shall apply to the product All such implied warranties are hereby and expressly disclaimed Limitation of liability ATN will not be liable for any claims actions suits proceedings costs expenses damages or liabilities arising out of the use of this product Operation and use of the product are the sole responsibility of the Customer ATN s sole undertaking is limited to providing ...

Page 8: ...nden Ave Suite 1B South San Francisco CA 94080 phone 800 910 2862 650 875 0130 fax 650 875 0129 European Office phone 44 0 870 0111286 fax 44 0 845 3349142 The following countries can use our toll free number 00 800 9102 8620 Austria France Germany Holland Italy Spain Sweden Switzerland www atncorp com 2006 ATN Corporation ...

Reviews: