4-6
SEq.
NO.
MalFuNcTION
TEST OR INSPEcTION
cORREcTIVE acTION
4
Diopter adjust-
ment cannot
be made
Check to see if the
diopter adjustment rings
are bent or broken
If damaged, refer
to higher level of
maintenance.
5
Battery adapt-
er difficult to
remove.
Check for damaged bat-
tery adapter.
If damaged, refer
to higher level of
maintenance.
6
Ir illumina-
tor fails to
activate.
In a dark location with
system turned on, acti-
vate Ir. visually check
Ir illuminator
operation;
scene should brighten.
If Ir illuminator fails
to activate, refer
to higher level of
maintenance.