Motor pole and speed comparison
2P=3000rpm around, 4P=1450rpm around
,
6P =960rpm around, /50Hz
,
2P=3600rpm around, 4P =1750rpm around, 6P =1200rpm around, /60Hz
,
Press ">>" to view the running status.
b-00 is output frequency. b-08 is Input/output terminal state.
b-01 is set frequency. b-07 is running time.
b-02 is output voltage. b-09 is analog input VI.
b-03 is output current. b-10 is analog input CI.
b-04 is bus bar voltage. b-11 is external pulse width input value.
b-05 is module temperature. b-12 is VFD rated current.
b-06 is motor speed. b-13 is VFD rated voltage.
b-14 is water supply control when the set pressure of the pipeline.
b-15 is water supply control feedback pipeline pressure.
VFD and single phase motor wiring.
1. Keeping the capacitor, Connect the motor to the UW or VW of the VFD. Reverse the motor according to the
motor nameplate.
2. Remove the capacitor, the wiring method for forward rotation and reverse rotation is as follows: