<Table 1>
Model
#of
burners
and control
method
Gas
Species
Intake-tub
e pressure
(
in.W.C.
)
Per BTU
B.T.U./h
Total BTU
B.T.U./h
Nozzl
e No.
ATTG-2
4
2 pieces
Independen
t control
Natural
Gas
4
25,000
50,000
#42
L.P. Gas
10
25,000
50,000
#53
ATTG-3
6
3 pieces
Independen
t control
Natural
Gas
4
25,000
75,000
#42
L.P. Gas
10
25,000
75,000
#53
ATTG-4
8
4 pieces
Independen
t control
Natural
Gas
4
25,000
100,000
#42
L.P. Gas
10
25,000
100,000
#53
5. Transport and Storage
In the process of transportation, handle carefully and keep upright to prevent
damage of the product packing. Wrapped equipment should not be in open air for a
long time, and shall be placed in a well-ventilated and non-corrosive gases warehouse.
When equipment needs temporary storage, waterproof measures should be taken.