The AG-811 is a Gateway dedicated to work with central controlling and monitoring systems.
It supports two-way communication with server through LTE/GSM or Ethernet

1

. It has inbuilt

timer with 10 ON/OFF schedule within 24h, auto configurable sunrise/sunset timer based on
geolocation   and   has   3   independent   relays   with   NO/NC   outputs.   Every   output   can   be
controlled   by   separate   time   schedule.   Gateway   has   isolated   Modbus   RTU   interface   to
communicate with energy meters, PLCs and other Modbus devices. It can be configured by:
internal website, SMS, string from server and configuration file loaded in predefined URL. For
accurate time and location it has GPS and RTC.

Gateway is for use in street light control panels and other application where it is needed to
control accurate on/off time with support of Modbus devices. It can be controlled remotely
from server or via SMS or also work in stand alone mode.

The AG-811 has advance alert option with 10 mobile number list for SMS alerts. In superCap
models there is power backup with power loss alert facility.

1.1.

Features

LTE and GSM connectivity

GNSS for accurate time and location

3 independent NO/NC outputs

Opto-isolated Modbus RTU

2 opto-isolated digital inputs

SMS alert and with mobile number filtering

Timer with astronomical timer

Internal website for configuration

LAN with PoE

Output status control by string from server and by SMS

Modbus archive data in internal memory

Aluminium compact size casing

35mm DIN rail mounting

1.2.

Technical specification

Technical specification is mentioned on separate document. Please visit 

product page

1

The current firmware version does not support SSL over Ethernet

           

www.atreyo.in

  ARAD/AG-811/HG/2022/02 – preliminary

 Page |3

Summary of Contents for AG-811

Page 1: ...HARDWARE GUIDE AG 811 CCMS gateway with timer 3 outputs and LTE www atreyo in ARAD AG 811 HG 2021 02 preliminary Page 1 ...

Page 2: ...8 NO NC outputs 8 4 System functions 9 4 1 Schedule timers for control outputs 9 4 2 Astronomical timer for control outputs 9 4 3 SMS alerts 9 4 4 Configuration of device 9 4 5 Power supply 9 4 6 Mounting place and condition 10 5 Wiring example 11 5 1 Example 1 with 24V external power relays contractors 11 5 2 Example 2 with common 230V supply for power relays contractors 12 5 3 Example 3 with sep...

Page 3: ...it is needed to control accurate on off time with support of Modbus devices It can be controlled remotely from server or via SMS or also work in stand alone mode The AG 811 has advance alert option with 10 mobile number list for SMS alerts In superCap models there is power backup with power loss alert facility 1 1 Features LTE and GSM connectivity GNSS for accurate time and location 3 independent ...

Page 4: ...Hardware Guide AG 811 2 Layout 2 1 Layout and connector functions Top panel view Connector panel view www atreyo in ARAD AG 811 HG 2022 02 preliminary Page 4 ...

Page 5: ...y Antenna LTE and GNSS All necessary pluggable connectors DIN rail clamp with screws 2 4 Optional accessory High gain LTE antenna panel mount combo antenna APS 10W24 3 phase power supply 24V 1A adapter power supply www atreyo in ARAD AG 811 HG 2022 02 preliminary Page 5 ...

Page 6: ...rking condition permanent ON POWER Low high voltage supply blinking 2 times per second ACT Normal working condition blinking every 1 second Serial RX and TX data indication of RS485 blinking on data transfer Inputs Input 1 and 2 high level indication ON if input high Outputs Out 1 3 ON ON on output ON 3 3 LAN and PoE The LAN interface use standard RJ45 8 pin connector with LED indicators The conne...

Page 7: ...ange It is possible to directly send and receive any value of register from server Please follow proper connection of A and B signals from device to A and B signals in power meter If the polarity is reversed there will be no data transmission All modbus configuration like baud rate parity address available in internal website The device provide on board 120Ω termination resistor for RS 485 port 3 ...

Page 8: ...C Inputs support only DC signal with proper polarisation The input digital high is from 3 5V to Vmax and digital low from 0 to 2V Inputs can be controlled also by open collector circuit with common positive The input resistance is approx 2 7k The input terminal diagram is as per below 1 2 digital input positive 1 2 digital input negative If by mistake reverse polarity signal is connected to input ...

Page 9: ... IP address of device 192 168 10 50 It is necessary to make proper configuration of LAN network in laptop SMS commands Device allow to make configuration by SMS command There is option to filter allowed mobile number to make configuration String from TCP IP server By the command from server it is possible to make all configuration But initially it is necessary to set server configuration in device...

Page 10: ...The device is dedicated to use in environment that is clean and protected from water and dust It can be used inside electrical panel boxes outdoor and without box in indoor application Mounting on standard 35mm DIN rail Device can be placed in any direction Protect device from direct sunlight and any other heat source www atreyo in ARAD AG 811 HG 2022 02 preliminary Page 10 ...

Page 11: ...or control lighting with external high power DC24 coil relays The inbuilt relays in the device drive with 12 24V DC external relays The switches can be used for sending information to server about such cases like open the door of panel switching to manual option or any other www atreyo in ARAD AG 811 HG 2022 02 preliminary Page 11 ...

Page 12: ...n 230V supply for power relays contractors The example with power relay contactor powered by single 230V AC In this example the separate power is provided for relays but common for all relays www atreyo in ARAD AG 811 HG 2022 02 preliminary Page 12 ...

Page 13: ...dware Guide AG 811 5 3 Example 3 with separate power for relay contractor This example is with separate relay power Each relay from different phase www atreyo in ARAD AG 811 HG 2022 02 preliminary Page 13 ...

Page 14: ...re Guide AG 811 5 4 Example 4 single phase direct drive This is example for direct driving the load Ensure maximum load not exceed 300W on every output www atreyo in ARAD AG 811 HG 2022 02 preliminary Page 14 ...

Page 15: ...rks Atreyo and the Atreyo logo are registered trademarks of Atreyo Research and Development LLP All other trademarks and copyrights are the property of their respective owners 6 3 Disclaimer All dimensions mentioned in the drawings are not to scale and may vary differ due to construction contingencies and site conditions which are subject to change as may be decided by the company The specificatio...

Reviews: