background image

Measuring

 

Accuracy

 

      current 

± 0.5% FS + 5dgt 

frequency 

± 0.01% FS + 5dgt 

power 

± 0.5% FS + 5dgt 

Setting 
accuracy

 

voltage

 

± 1% FS 

frequency 

± 0.1% FS 

            Interface

 

RS232C 

Current limit setting

 

0-Max Current (the maximum current is: maximum capacity / 240V , ie P / 240 )

Output protection

 

Overcurrent, Over Current, Over Temperature, Over Temp, Overload, Over Load short-

circuit, Short Circuit

 

Weight

 (Kg) 

20

.6 

23 

3

0.5 

3

3.3 

48 

80 

      WxHxD (mm) 

4

80x135x515

 

4

80x225x53.5 

Operating environment

 

0~40

°

C  20-80% RH 

480*240*590 430*590*810

Summary of Contents for APS-4000 Series

Page 1: ...APS 4000 APS 7000 series AC Frequency Conversion Power Supply User Manual MATRIX TECHNOLOGY INC ...

Page 2: ...e in unsafe places 1 Safety instructions Before using this AC variable frequency power supply please read this operating instruction completely and fully understand the safety signs used by this machine for safety Please select the correct input voltage specification before turning on the input power switch of this machine To prevent accidental injury or death professionals must connect the input ...

Page 3: ...The user must not change the circuit or parts of the machine by themselves If it is changed the warranty period of the machine will automatically expire and our company is not responsible The use of parts or accessories not approved by our company is also not guaranteed If the machine returned for inspection is found to be changed our company will restore the circuit or parts of the machine to the...

Page 4: ... Check before use 1 Before the input power supply wiring the power required for this machine all switches should be placed in OFF position Please connect the wiring according to the logo 2 Please make sure all the wiring is correct before starting 3 The model will be displayed on the screen when the computer is turned on and the CPU will call the last setting value before shutting down because the...

Page 5: ...ite 5 The installation site should be free from severe vibration or bumps 2 3 Storage and transportation Surroundings APS series AC variable frequency power supply can be stored and transported under the following conditions Ambient temperature the Temp 20C to to 60C The height of the Height 7620 meters This machine must avoid abrupt changes in temperature which may cause moisture to condense insi...

Page 6: ...e is placed can withstand 150Kg multilayer carton packaging 3 around the machine must be filled shockproof material a thickness of about 70 to 100mm 4 properly sealed box 5 marked easy and scrap Please handle with care ...

Page 7: ...A Load 1 T H D 2 low end 120V high end 240V with pure resistive load Frequency stability 0 01 LED Display Voltage Vrms current Arms frequency power power factor Voltage resolution 0 01V Frequency resolution 0 01Hz Current resolution 0 001A Memory M1 M5CV F A Measurement accuracy voltage 0 5 FS 5dgt current 0 5 FS 5dgt frequency 0 01 FS 5dgt power 0 5 FS 5dgt Setting accuracy voltage 1 FS frequency...

Page 8: ...cy 47Hz 63Hz OUTPUT Voltage 0 150VAC to 0 310 VAC AUTO 0 600V can be customized frequency 45 500Hz 0 1Step Maximum current L 120V 4 2A 8 4A 16 8A 25A 42A H 240V 2 1A 4 2A 8 4A 12 5A 21A Load regulation rate 1 T H D 2 low end 120V high end 240V with pure resistive load Frequency stability 0 01 Significantly small Voltage Vrms current Arms frequency Fre power Watt x power factor PF Voltage resolutio...

Page 9: ...232C Current limit setting 0 Max Current the maximum current is maximum capacity 240V ie P 240 Output protection Overcurrent Over Current Over Temperature Over Temp Overload Over Load short circuit Short Circuit Weight Kg 20 6 23 30 5 33 3 48 80 WxHxD mm 480x135x515 480x225x53 5 Operating environment 0 40 C 20 80 RH 480 240 590 430 590 810 ...

Page 10: ...Chapter 4 Introduction of Operation Panel 4 1 Panel function introduction APS 4000 series front panel APS 4000 series rear panel APS 7000 series front panel APS 7000 series rear panel ...

Page 11: ... key FSET Frequency setting key I SET Maximum current setting key SYSTEM System setting key HIGH LOW High and low gear switching key P PF Power power factor switch Setting parameter up key APS5000AS column Setting parameter down key APS5000AS column Save key M2 Save key M3 Save key M4 Save key APS4000S column M5 Save key APS4000 series ON OFF Output switch reset button 5 1 Button layout APS4000 Se...

Page 12: ...y value APS5000A column only At the same time it can also be set by adjusting the knob In the range of 45 250HZ the minimum change is Q1HZ STEP others are the same as the voltage setting method 5 5 High and low voltage switching The voltage high low switch button when the low level output the rated current of the output is large and when the high end output the rated current of the output is halve...

Page 13: ...tput and last means the last state Communication protocol selection use the up and down keys to change the setting 0 to close the communication function ASCII protocol 2 to Hex protocol Not yet developed Output delay setting use the up and down keys knob to change the setting in seconds Communication address setting use the up and down keys knob to change the setting a 1 30 w Precautions Before us...

Page 14: ...ed please notify the maintenance department of our company and we will do good after sales service for you 6 2 Product maintenance 1 The quality guarantee period of this product is twelve months during which non human faults can be guaranteed free of charge 2 If the quality guarantee period is exceeded only Victoria s cost will be charged 3 Long term tracking and service and establish files for cu...

Page 15: ...wn keys to change the setting 0 is to close the communication function 1 is the ASCII protocol and 2 is the Hex protocol Agreement 2 The format of the host computer PC sending data to the power supply Device number ID 1 byte command code 1 byte operation code 1 byte data 4 byte check code 1 byte Device ID 1 28 ID number corresponding to each inverter power supply Command code ASCII HEX R 0x52 Read...

Page 16: ...status byte Whether the current is overloaded 1 Current overload 0 normal 0 clear current overload sign Byte 1 Power failure alarm 1 Power failure 0 normal 1 Reset to clear the alarm mark Byte 2 Is it currently in high end or low end1 high end 0 low gear be ignored Byte 3 Whether to output 1 output 0 No output be ignored 0x31 Target frequency Frequency value of 4 bytes unit 0 1 H B range 450 1200 ...

Page 17: ... Measuring frequency Not writable 3 Illustration assuming ID number is 0x01 the following are 16 hexadecimal 1 Set the automatic gear voltage 120V 01 57 33 B0 04 00 00 3F successful response 01 57 33 B0 04 00 00 3F 2 Provided autopilot voltage 240V 01 57 is 09 0000 3360 of the F4 success response 01 60 0900 00 57 is 33 is the F4 3 Setting grade voltage 120V 01 57 is 32 B0 04 00 00 3E success respo...

Page 18: ......

Reviews: