BX-Series Checkweighing Floor Scale
Side B
TM
Recharge LED
LED’s color indicates the 4 Charging States.
Green: Fully charged, 100% Charge.
Yellow: Recharging, 90% ~ 99%. Quick Charge.
Red: Recharging, 0% ~ 89%. Keep Charging.
Off: Scale running on battery only. No Charge.
Keypad
Gross/Net/Tare key, toggles the display
between Gross, Net, or Tare weights.
Unit key, used to toggle between the
different weighing units.*
Mode key, used to toggle between the
different weighing modes.*
Tare key, used to enter and clear tares.
Zero key, used to set the zero point.
Print key, for scales with serial ports only;
connects to serial printers.
To turn OFF, simply press this key.
To turn ON, hold down this key for 1 second.
Nomenclature & Pole Assembly
Displays
Indicates that there are 10 hours of battery power left.
NET
Indicates that the displayed weight is a net weight.
STABLE
Indicates that the weight is stable.
ZERO
Indicates that the scale is at zero (gross or net zero.)
GROSS
Indicates that the displayed weight is a gross
weight.
TARE
Indicates that the displayed weight is the tare weight.
HOLD
Indicates that the scale is in Hold mode.
Indicates that weight is above High Limit.
Indicates that weight is within Limits.
Indicates that weight is below Low Limit.
Specifications
Models:
BX-120
BX-150
BX-300
BX-600
150 x 0.05 lb 300 x 0.1 lb
600 x 0.2 lb
Capacities:
120 x 0.02 lb
300 x 0.05 lb 600 x 0.1 lb
Resolution: 1/6,000 and 1/3,000 Models; NTEP Approved CC# 06-035
LCD Displays:
Weight: 6 Digits, 999.999 max
Platter Size: Width: 420 mm / 16.5”
Length: 520 mm / 20.5”
Maximum Tare:
Full Capacity
Backlight Settings
1. Hold down
& release when display shows:
2. Press
.
3. Use
to select
on
,
oFF
, or
Auto
.
4. Press the
.
Auto Shutoff
1. Turn scale ON and press
while displays
are counting down.
2. Press
to select
0
,
1
,
5
, or
30
minutes.
3. Press the
key to save the setting.
Error Messages
Width: 420 mm / 16.5”
Length: 520 mm / 20.5”
Product
Dimensions
Height: 940 mm / 37.0”
AC Adapter: 120V AC, 60 Hz to 9V DC, 800mA, Positive Tip
Power:
AC Cord: 120V AC, 60 Hz, Approximately 10 Watts
Operating Temp: -10
°
C ~ 40
°
C / 14
°
F ~ 104
°
F
Charge Life: 100 hours without backlight
48 hours with backlight
Battery
Recharge:
12 hour Quick Charge gives 90 hours of use w/o backlight
© 2005, All rights Reserved
www.atronsystems.com
Code
Problem
Solutions
Err 4
The Initial Zero
or
the
Zero key is attempting to
zero a load that is
greater than 4% of max
capacity.
Remove all weight from
platter & turn ON; try to Zero
less weight;
or
scale needs
calibration / service.
Err 5
Keyboard error.
The keypad has a short and
it must be replaced.
Err 6
Load Cell error.
Check load cell cable on
back of display head for
proper connection.