background image

Easy Weigh LS-100-N Quick Reference Guide

 

Atron Systems, Inc.   

y

   4 York Avenue   

y

   West Caldwell, NJ  07006   

y

   tel:  973-227-8882   

y

   fax:  973-227-8820   

y

   www.atronsystems.com 

A.

 

Basic setup: 

1.

 

Take the scale, pole display, platter, and accessories bag out of the box. 

2.

 

Install the pole display:  

Note

:  Make certain that none of the wires are being crimped when you are installing the pole display. 

a.

 

Connect the display connectors together. 

b.

 

Place the Pole Display properly into the bracket making sure that the connectors are slipped inside of the 
pole (upwards.)   

c.

 

Attach the two display pole screws (2 larger screws) to securely fasten the pole to the bracket. 

d.

 

Finally, attach the bracket-plate to the bracket and fasten it with the 4 smaller screws. 

3.

 

Place the scale in the area where it will be used which should be a rigid and level surface.  Using the leveling feet and 
leveling gage, make sure that scale is level.  The leveling gage is located on the right-side rear of the scale by the pole 
bracket; the leveling feet are located at the bottom of the scale chassis.  

Note:

  The leveling foot located on the front-right 

side of the bottom of the scale (closest to the numeric keypad) is 

not

 adjustable.  Please 

do not

 try to adjust this leveling foot; 

instead, use the other three feet to adjust the level. 

4.

 

Place the platter on the scale platform and then connect the AC cord to the LS-100-N.  The AC cord (power cord) goes 
connected to the left-side of the scale; there is a label on the scale by the connector ports which indicates what each 
connector is for.

 

5.

 

Make sure that the power switch is in the OFF position which is located above the AC cord connector. 

6.

 

Plug the scale into an AC source.  

Note:

  The AC source must be 85V ~ 240V DC 50/60 Hz +5%.

 

7.

 

Turn the power switch to the ON position.  The scale will do the display test and then go to zero. 

8.

 

Press the 

 

FEED 

 key 2 or 3 times collecting the labels as they are fed out each time you press the key. 

9.

 

The scale should be in the 

Initial State

; all the displays should read:  

 

 

 

 

 

B.

 

How to program PLUs: 

Note:

  In order to save the PLU “as-is” you can press the 

SAVE

 key at any point in PLU programming. Pressing this key will store the 

PLU, print a PLU Verification Label, and take you back to step 3.

 

1.

 

Begin at the 

Initial State

 and then press the 

SET

 key. 

2.

 

Using the numeric keys, enter the 4 digit password and press 

PRINT

 

1

3.

 

Enter the PLU number you wish to 

Create

 or 

Edit

 and then press 

PRINT

or

 press 

 

ESC 

 

 

SET 

 to go back to the 

Initial State

.  PLU numbers can be up to 6 digits (1 to 9999.)  Keep in mind that PLUs 1 to 60 will be automatically 

assigned to Speed keys 1 to 60. 

4.

 

Press 

 

 for 

By Weight

 or 

 

 for 

By Count

5.

 

Using the Alpha-Keypad, type the name for this PLU’s 1

st

 Line and then press 

PRINT 

6.

 

Using the Alpha-Keypad, type the name for this PLU’s 2

nd

 Line and then press 

PRINT 

 3 times. 

7.

 

By Weight PLUs go to step 9

By Count PLUs go to step 8

8.

 

Enter the piece count for this By Count PLU and then press 

PRINT

.  The piece count can be from 1 to 99 (2 digits).  

To price something at “3 for $1.00”, you would enter “3” here and at step 9 you would enter “1.00” to get 3 for $1.00.   
If the By Count Multiply feature is set up by your 

Authorized Dealer

, then this would function as “3 x $1.00” instead. 

9.

 

Enter the Unit Price for this PLU and then press 

PRINT

.  The Unit Price can be 6 digits (0.00 to 9999.99.)  This is the 

“Price-per-Pound” for a By Weight PLU or the “Price-per-Piece” for a By Count. 

10.

 

Enter the Shelf Life for this PLU and then press 

PRINT

.  The Shelf Life can be 3 digits (0 to 366) and is the number of 

days used to calculate the “Sell By” date that can be printed on the label.  If you set the Shelf Life to 0 then the “Sell 
By” date will not be printed on the label; if Shelf Life = 1 then the “Sell By” date will be the same as the “Packed On” 
date; if Shelf Life = 2 then the “Sell By” date will be the “Packed On date + 1”; etc. 

11.

 

(

By Count PLUs go to step 12

)  Enter the Tare weight for this PLU and then press the 

 

PRINT 

 key.  The Tare weight 

can be 4 digits (0.00 to 29.99) and is the weight of the container for this PLU.  Tare weight is in pounds. 

12.

 

(

By Weight PLUs go to step 13

)  Enter the Net Weight Statement for this PLU and then press 

PRINT

.  The Net 

Weight Statement can be up to 4 digits (0 to 9999) and is the approximate weight of the commodity for this PLU.  Net 
Weight is in ounces (not weighed by scale) and it needs to be “the same or less than” the actual weight of the product. 

13.

 

Enter the 1

st

 Line of Ingredients for this PLU and then press 

PRINT

.  You can have up to 56 characters for every line 

of Ingredients and there is a maximum of 10 lines. 

14.

 

Enter the 2

nd

 Line of Ingredients for this PLU and then press 

PRINT

.  You can continue doing step 14 until you reach 

Line 10.  Once you are done typing the Ingredients for Line 10, you can press 

PRINT 

 to save the PLU and go back to 

step 3; 

or

 you can press 

 

SAVE 

 to save the PLU, print a PLU verification label, and then go back to step 3. 