7
March 2006
Bill Acceptor - JCM UBA-10-SS
Inspecting and Cleaning
When to Inspect and Clean
Inspecting and cleaning the UBA unit are tasks you
should perform during routine preventive
maintenance.
Procedure to Inspect
• Press down the transport unit release lever and
pull out the transport unit.
• Access the bill path by opening the transport unit.
• Make a visual check to see if any debris or liquid
have collected in the bill path.
• Check the belts (also in the transfer and stacker
units) to see if they are frayed, slick or worn.
If so, replace them.
• Check the sensor lenses to see if they have be-
come dirty, clouded or scratched.
If so, replace scratched or clouded lenses.
• Inspect if lenses are set flush with the bill path. If
not, open and press lenses back into position.
Procedure to Clean
• If possible, use compressed air for blowing debris
from the bill path and the cashbox.
• Use a lint-free cloth and a mild liquid detergent
mixed with water, such as dish detergent, or just
water.
• Ensure that the cloth is not liquid-saturated.
• Wipe the bill path, lenses and rollers.
• Wipe the belts lightly as you rotate them by hand.
• After wiping, inspect lenses to ensure that none
have been moved out of position.
• Allow drying before closing the acceptor and trans-
port assembly.
O
PERATING
dirty lenses dirty roller
after cleaning after cleaning
Note:
Never use dry abrasive type cleaners,
alcohol or any kind of solvent for cleaning
the acceptor. These products can damage
lenses and belts!