7
MANU3610-01
Terminal Cabling
Select and remove the seal tight connector(s) and corresponding nylon plug(s) located on the
outside
of the
housing. Remove the hinged cover and pass the data cable through the appropriate seal tight connector. Secure the
data cable to the interface board in the base of the Series 3610 terminal (Figure 2). Tighten the seal tight connector
down over the cable. Attach the output of the 12VDC power pack assembly (if power is not combined within the
communication cable) into the power jack (PJ1) in the base of the Series 3610. The supplied rubber tubing should
be installed if the seal tight connectors do not properly secure either cable. Place the jumper, located at JP1 on the
I/O board, to the NC position (Figure 2). Plug the primary of the power pack assembly to a conventional wall
outlet.
With the terminal’s Use/Test switch in the Use mode (Figure 1), replace the enclosure’s hinged cover.
The Series 3610 will power-up and display the on-line default message. (
Refer to the ATS SETUP MODE section
of this manual for terminal communication setup parameters
.) Attach the remaining end of the data cable into the
host computer port. The Series 3610 is now ready for operation.