12

TROUBLESHOOTING GUIDE

 

PROBLEM   

 

 

CAUSE 

 

 

       CORRECTION

U.V. lamp will not light   

Check input voltage if below 

 

Install a voltage regulator

     or 

above 

120 

volts

     Line 

cord 

disconnected 

 

  Check, 

replace  

     or 

outlet 

defective

     Defective 

U.V. 

lamp 

   Replace

     Defective 

lamp 

ballast 

  Check 

output 

voltage

           Replace 

ballast

     Loose 

open-circuit 

wire 

  Trace 

out 

and 

repair

      

Leak at quartz nipple 

 

Defective or cracked O-Ring 

 

Replace O-Ring

     

 O-Ring 

not 

seated 

properly 

  Replace 

O-Ring

Summary of Contents for Safe Lite SL-2V

Page 1: ...Models SL 2V 8V It is important that those responsible for the installation of this equipment as well as the owner operator read this manual and carefully follow the instructions and guidelines Revis...

Page 2: ...r sold by the manufacturer distributor may cause an unsafe condition 7 Intended for indoor use Do not install this disinfection system where it will be exposed to the weather Do not store this disinfe...

Page 3: ...Flow rate must not exceed rated capacity of the unit DESCRIPTION OF EQUIPMENT The Safe Lite series are of unique design with an ultraviolet germicidal lamp housed within a single quartz sleeve surroun...

Page 4: ...personnel look at a U V lamp in operation EXCEPT through an external Site Port lens located on the outside of the unit 3 U V disinfection units must always be properly grounded INSTALLATION The Safe L...

Page 5: ...selected Simply hand press or slightly tap in the flow control until it sits on the inside ledge of the machined port 3 Using the mounting box provided secure unit to wall or other surface Make sure t...

Page 6: ...eposit onto the quartz sleeve After sufficient film has formed on the quartz sleeve the ability of the ultraviolet germicidal rays to pass though the quartz sleeve and into the water may be impaired T...

Page 7: ...shortwave U V to effectively kill bacteria Failure to replace the U V lamps every 9 000 hours may cause bacteriological breakthrough Should the use of the disinfection unit be intermittent in no case...

Page 8: ...o determine how much chlorine solution should be used In some instances removing the seal to measure the water can be a difficult task and it is easier to guess at the quantity of disinfectant needed...

Page 9: ...w to protect wells and springs and keep them from becoming contaminated call or visit your local Cooperative Extension office or your nearest certified water treatment specialist TABLE 1 Quantity of s...

Page 10: ...ater System Using Well Sanitizer Pellets Table 1 Well Diameter Inches Weight of Pellets lbs oz Cups of Pellets Number of Pellets To produce a 400 P P M chlorine dosage NOTE Pellets Weight 1 14 gram ea...

Page 11: ...n water back down the well this also rinses upper portion of well After about 15 minutes of recirculation the water a strong chlorine odor should be apparent Turn off hose 6 Bypass water softener and...

Page 12: ...gulator or above 120 volts Line cord disconnected Check replace or outlet defective Defective U V lamp Replace Defective lamp ballast Check output voltage Replace ballast Loose open circuit wire Trace...

Page 13: ...proval by Aqua Treatment Service Inc the Dealer Distributor should return the item to Aqua Treatment Service Inc 194 Hempt Road Mechanicsburg PA 17050 prepaid If a part proves to be defective it will...

Page 14: ...120V 03 03 AMPS 120V 25 25 INLET OUTLET SIZE 3 8 STD MNPT 3 4 STD MNPT TOTAL DIMENSION INCL WALL MOUNT L X W X D 15 5 X 5 X 5 21 X 5 X 5 DISINFECTION CHAMBER MATERIAL WETTED PARTS 304 SS TUBING 304 SS...

Page 15: ...bottle or sterile container being used Holding the cap in a down position the operator should then hold his breath while taking the sample so as to avoid oral contamination of the sample The operator...

Page 16: ...16 WIRING DIAGRAM...

Page 17: ...17...

Page 18: ...18...

Page 19: ...19 DRAWING AND PART NUMBERS...

Page 20: ...20 SL 2V Explosion...

Page 21: ...1 4 ATS 5171 Sight Port Nut 1 5 ATS 6110 Box 1 6 ATS5 410 Lock Nut 1 7 ATS8 544 End Nut O Ring seal quartz sleeve 1 8 ATS 7091 Gaynor Connector 1 9 ATS5 409 Brass End Nut 1 10 ATS 6111 Cover 1 11 ATS1...

Page 22: ...22 SL 8V Explosion...

Page 23: ...Retainer 8 gpm 1 6 ATS F08 8 gpm Flo Et 1 7 ATS 6110 Box 1 8 ATS5 410 Lock Nut 1 9 ATS8 544 End Nut O Ring seal quartz sleeve 1 10 ATS 7091 Gaynor Connector 1 11 ATS5 409 Brass End Nut 1 12 ATS 6111 C...

Reviews: