7
Behavior in cases of error
Defective operational readiness of the system may be due to a simple error. Check the system for the listed
sources of error.
If the error cannot be removed after an inspection to the named causes, then inform customer service or
your dealer.
Independent repair work on safety devices of the lift and checking the electrical system
may only be done by specialists.
Problem: Motor does not start
Possible causes:
Remedy:
No power supply
Check the power supply
The main !;itch (1) i! not !;itched on, or i! defective
Check the main !;itch (1).
Defective fuse
Have fuses checked
The
o
"Lift" (2) button i! defective
Inform customer service
Motor has overheated
Let the water cool.
Cooling time depends on the ambient temperature.
Motor defective
Inform customer service
Problem: Motor starts, load is not lifted
Possible causes:
Remedy:
Load is too heavy
Unload the lift
+ydraulic oil filling level i! too lo;
Refill hydraulic oil
Emergency di!charge fi’ture i! not clo!ed
Check emergency di!charge fi’ture
Pressure line leaking
Inform customer service
Hydraulic pump defective
Inform customer service
The coupling between the motor and pump is
defective
Inform customer service
Defective cylinder
Inform customer service
Pressure relief valve is defective
Inform customer service
Problem: The lift cannot be lowered
Possible causes:
Remedy:
Lifting table is sitting on an obstacle
See 7.1 Moving onto an obstacle
Hydraulic valve defective
Inform customer service
The
o
"Lo;er" (3) button i! defective
Inform customer service