Quality system 

Each ‘ATEX-product’ that leaves our factory is produced and approved whether it meets all ATEX quality requirements. The 
results of each check are logged. Further IPS keep file logging (and store this logging for 10 years) per batch where these 
products are shipped to when they leave our factory. This enables us to trace the delivered products through the delivery chain, 
where each link in this delivery chain must register to whom ATEX products were supplied ultimately tracing the actual user of 
the ATEX product. This is a very important aspect of the ATEX regulations to enable appropriate measures in case a non-
conformity related to a product is detected. 

 

3.3.2 

Identification of ATEX certified products 

Each ATEX certified product can be identified separately. The data indicated on the products gives all relevant information like: 
 

- Serial number   

 

- Production week 

 

- Product identification 

- Address manufacturer   

- Ingress Protection (IP) 

 

- CE m ID number 

- ATEX marking  

 

- Protection concept 

 

- ATEX certificate number 

- Country of production   

 

3.3.3 

Traceability of ATEX certified products 

Each ATEX certified product must be traceable (where is it, who is using it?). So every link in the supply chain must  
keep records of the location of ATEX products i.e. who is using them, like: 

 

The manufacturer keeps logs of to which distributor products are supplied.  

 

The distributor does the same and every following link as well.  

 

In the end the final organization that using it, must keep logs of which employee is using the device (where is it, who has it?). 

In this way every ATEX product is traceable making it possible to find and contact the user in case this might be required. 

 

3.3.4 

Putting into service 

The Mobile may only be put into service at the site by the "system manager", the person responsible for the safety of people 
using equipment in areas which have a potential explosive atmosphere. This system manager must be acquainted with the risks 
for the user at the places where the mobile will be used. Before the mobile is put into service the user should receive 
instructions and information about the conditions to be followed for the safe operation.  
All relevant data concerning commissioning and repairs on ATEX products must be logged. Only a service organisation 
acknowledged by the manufacturer may perform repairs. For traceability it is advisable to keep a record of type- & serial 
numbers of the mobiles and the customers/end-users who have received that mobiles. 
 

 

Warning: The use of any not by Atus released spare part will make that the product loses its ATEX status. 
                the product is no longer suitable to working in potentially explosive atmospheric conditions then 
                A special warning for the battery: use only battery type: F01U168323. 

 
 

3.3.5 

The following items should be a guide for the instructions 

 

Defining the area where the PS3-BAX mobile may be used. 

 

The special conditions of use, including examples of possible misuse, for which experience has shown that they might 

occur. 

 

Inside the defined area the mobile may not be opened. 

 

Inside the defined ATEX area the batteries of the mobile may not be charged 

 

Outside the defined area the batteries of the mobile may only be charged by using dedicated chargers. 

 

Only the battery types mentioned on the ATEX-certificate may be used: F01U168323. 

 

A defect mobile should immediately be brought outside the ATEX-area. 

 

If the user is in doubt about the use of the mobile in the ATEX area, he/she should contact the system manager. 

 

 

Warning: When working in potentially explosive atmospheric conditions, every precaution must be taken to avoid the 
risk of initiating combustion. Mobiles with ATEX approval must be in possession of an approved certificate  
issued by the certification authorities. NON-ATEX Mobiles must never be used in such conditions. 

 
 

3.4  Declaration of Conformity 

Hereby, International Pagerservices B.V. declares that this PS3-BAX is in compliance with the essential 
requirements and other relevant provisions of Directive 1999/5/EC. 
 

 
 
 
 

Summary of Contents for PS3-BAX

Page 1: ...ATEX Instructions for Use IFU_PS3 BAX_En_1816 IFU Personal Security Pager ATEX version PS3 BAX Personal Security Pager with location detection Manual Automatic alarms and Voice ATEX version ...

Page 2: ...Mobile 5 3 2 Explanation of the Product s label 5 3 2 1 General product data example 5 3 2 2 ATEX related data on the label 5 3 2 3 ATEX Certificate information 6 3 2 4 Special Condition for Safe Use 6 3 2 5 Other requirements for Safe Use 6 3 3 General rules applicable for ATEX products 7 3 3 1 Quality system 7 3 3 2 Identification of ATEX certified products 7 3 3 3 Traceability of ATEX certified...

Page 3: ...ct if you do not obey the instruction Warning General sign for cautions warnings and dangers Caution Risk of electrical shock Note The general sign for a note 1 4 Examples The manual contains numerous examples for instance in the form of screen shots Please note that the examples may differ more or less from you situation depending on version differences settings configuration details resolution e...

Page 4: ...r Four automatic alarm calls Tear Off Man Down No Move and Fast Move alarm Receive and handle text messages Receive speech messages Transmit Speech messages Only for PS3 versions Location detection Self monitoring and system scanning functions Self test functions The PS3 BAX is applicable to be used in Potentially Hazardous environments as specified for ATEX regulations Icon Description Icon Descr...

Page 5: ...NL the Netherlands CE mark refers to the telecom directive 1999 5 EC and the ATEX directive 2014 34 EU The number 0344 refers to the identification number of the notified body KEMA consulted for the approval and for the recognition of the required Quality Assurance System The Ex logo indicates that it is an ATEX explosion Safe product IP 65 Industrial protection 6 for dust 5 for water is irrelevan...

Page 6: ... there is one or more Special condition of Safe Use See for details below 3 2 4 Special Condition for Safe Use If the PS3 BAX Personal Security Mobile is used in a dry area with a relative humidity 60 or when the users wears cloths which could cause dangerous electrostatic discharges the mobile must be used with leather carrying case type LBB5302 00 12NC 8900 530 20005 Contact your supplier for or...

Page 7: ...ng equipment in areas which have a potential explosive atmosphere This system manager must be acquainted with the risks for the user at the places where the mobile will be used Before the mobile is put into service the user should receive instructions and information about the conditions to be followed for the safe operation All relevant data concerning commissioning and repairs on ATEX products m...

Page 8: ...ervices B V Willem de Haastraat 5 5421 TN Gemert The Netherlands http www atusbv com https pagerservices nl 2018 International Pagerservices B V All rights reserved Data subject to change without notice IFU_PS3 BAX_En_1816 ...

Reviews: