background image

 

 

 

Literature number 31971 

hydro flame

™ 

AFM Series Furnaces Models  

AFMD16 
AFMD20  
AFMD25 
AFMD30  
AFMD35 

Technical Installation Manual 

1120 North Main Street • Elkhart, IN 46514 
USA & Canada : 1-866-869-3118 
Internet: http://www.atwoodmobile.com 

 

English, Français (et Canada) 

This instruction manual is for use by an authorized service technician to 
install  an  Atwood  – 

hydro  flame

™  furnace.  Should  you  require  further 

information, contact your dealer or Atwood Mobile Products LLC. 
This  furnace  design  has  been  certified  for  installation  in  recreation 
vehicles  as  a  MSP  Category  III  furnace.  Follow  this  installation 
instruction  to  insure  safe  operation  of  the  furnace.  Failure  to  install 
furnace  according  to  this  installation  instruction  nullifies  the  furnace 
warranty. 

 

 

  

 

 
 
 

Effective 5/2014 

 WARNING

 

Installation of this appliance must be made in accordance with the written 
instructions provided in this manual. No agent, representative or 
employee of Atwood or other person has the authority to change, modify 
or waive and provision of the instructions contained in this manual.

 

 

 

WARNING 

Avoid possible injury or death 

Improper installation, adjustment, alteration, service or maintenance can 
cause  property  damage,  personal  injury  or  loss  of  life.  Refer  to  the 
installation  instructions  and/or  owner’s  manual  provided  with  this 
appliance. A qualified installer, service agency or the gas supplier must 
perform installation and service. 
 

 

 CRITICAL INSTALLATION WARNINGS 

  DO NOT install furnace on material that restricts return air, like carpet 

or any soft material such as vinyl. 

  DO NOT install furnace where clearance to combustibles cannot be 

maintained. 

  DO NOT modify furnace in any way. 

  DO NOT alter furnace for a positive grounding system. 

  DO NOT hi pot furnace unless electronic ignition system (circuit 

board) has been disconnected. 

  DO NOT use battery charger to supply power to DC model furnace 

even when testing. 

  DO NOT use 120-volt AC current with DC models. 

  DO NOT use furnace cabinet area as a storage compartment. 

  DO NOT vent furnace with venting system serving another appliance. 

  DO NOT vent furnace to an outside enclosed porch area. 

  DO NOT use for temporary heating of buildings or structures under 

construction. 

  Protect building materials from degrading from flue gas exhaust. 

  Protect furnace electrical components from water. 

  Compartment must be closed when operating unit. 

  Should the gas supply fail to shut off or if overheating occurs, shut off 

the gas valve to the furnace before shutting off the electrical supply. 

  DO NOT use this furnace if any part has been under water. 

 
 

 CAUTION 

PERSONAL INJURY 

All  sheet  metal  edges  are  sharp  care  should  be  taken  when 
handling or brushing up against them. 

 

 FOR YOUR SAFETY 

Do not store or use gasoline or other flammable vapors and liquids in the 
vicinity of this or any other appliance.

 

 WARNING

 

Be sure the furnace and all ignition systems are “off” during any type of 
refueling and while vehicle is in motion or being towed.

 

TO THE INSTALLER:

 

  LEAVE THIS MANUAL WITH 

THE APPLIANCE. 

TO THE CONSUMER:

  

RETAIN THIS MANUAL FOR 

FUTURE REFERENCE.

 

SAFETY ALERT SYMBOLS 

Safety Symbols alerting you to potential personal safety 

hazards obey all safety messages following these symbols 

 

WARNING 

Avoid possible injury or 

death 

 

CAUTION 

Avoid possible injury 

and/or property damage 

 WARNING 

FIRE OR EXPLOSION

 

If the information in this manual is not followed exactly, a 
fire  or  explosion  may  result  causing  property  damage, 
personal injury or loss of life. 

FOR YOUR SAFETY 

WHAT TO DO IF YOU SMELL GAS: 

  Extinguish any open flame. 

  Evacuate all persons from the vehicle. 

  Shut off the gas supply at the gas container or 

source. 

  Do not touch any electrical switch, or use any 

phone or radio in the vehicle. 

  Do not start the vehicle’s engine or electric 

generator. 

  Contact the nearest gas supplier or qualified 

service technician for repairs. 

  If you cannot reach a gas supplier or qualified 

service technician, contact the nearest fire 
department. 

  Do not turn on the gas supply until the gas 

leak(s) has been repaired. 

A qualified Service Technician 

Service Center or gas supplier must perform 

installation and service. 

 

Summary of Contents for AFMD16

Page 1: ... cabinet area as a storage compartment DO NOT vent furnace with venting system serving another appliance DO NOT vent furnace to an outside enclosed porch area DO NOT use for temporary heating of buildings or structures under construction Protect building materials from degrading from flue gas exhaust Protect furnace electrical components from water Compartment must be closed when operating unit Sh...

Page 2: ...1 AFMD20111 AFMD20121 AFMD25111 AFMD25121 AFMD30111 AFMD30121 AFMD35111 AFMD35121 Type of Gas LP Propane LP Propane LP Propane LP Propane LP Propane BTU Input 16 000 20 000 25 000 30 000 34 000 BTU Output 12 160 15 200 19 000 22 800 25 840 Duct Static Pressure 20 WC 10 WC 10 WC 10 WC 10 WC Amperage AMPS 4 2 4 2 7 5 7 5 11 1 Watts 50 50 90 90 132 Power Supply Volt DC 12 12 12 12 12 Return Air 80 in...

Page 3: ...ere wires pipes or other objects will interfere with installation or operation of furnace DO NOT install furnace on material that restricts return air such as directly on carpet or soft material like vinyl If you must install furnace on carpet or soft material install furnace on cleats or on a wood or metal panel extending the full width and depth of furnace plus minimum clearance to combustibles ...

Page 4: ...ezel creating a sealing area 3 Pull furnace forward through cutout about a 1 inch slip bezel around casing and flush inner flange with casing 4 Secure bezel to furnace casing with 6 screws 5 Push furnace and bezel back tight against side wall and secure with 14 screws 6 When installing screws DO NOT deform bezel 7 Connect the gas line to the valve and push the gas line plug into casing opening 8 R...

Page 5: ... needed to maintain installation duct air flow requirements DO NOT install floor registers within 2 feet of return air openings See ducting option from casing top and bottom areas These options can be with flex ducting or by hard ducting installations Hard ducting must be sealed to insure proper operation of the appliance HORIZONTAL OR VERTICAL BOTTOM DISCHARGE Figure 6 Units can be installed as b...

Page 6: ...or servicing Wiring errors can cause improper and dangerous operation Verify proper operation after servicing Disconnect electrical power before servicing CAUTION PROPERTY DAMAGE This connection is for low voltage battery or direct current only Do not connect to 120 or 240 volts AC POWER SUPPLY Atwood Mobile Products highly recommends the use of an electronic solid state converter with clean power...

Page 7: ...come on 6 Allow 30 seconds for main burner to light after blower comes on This furnace is equipped with an ignition device which automatically lights the burner DO NOT try to light the burner by hand 7 If burner does not light repeat Steps 1 through 5 8 If after three 3 attempts with no ignition go to shut down and contact your dealer or a local recreational vehicle service agency Do not continue ...

Page 8: ...8 WIRING AND LADDER DIAGRAM ...

Page 9: ...9 PART DRAWINGS PART LISTS ...

Page 10: ...10 ...

Page 11: ...11 ...

Page 12: ...nt de rangement NE PAS aérer la fournaise avec un système de ventilation pour entretenir un autre appareil NE PAS aérer la fournaise à un endroit extérieur fermé comme une véranda NE PAS utiliser pour le chauffage temporaire de bâtiments ou de structures en construction Protégez les matériaux de construction contre la détérioration par l échappement de gaz à combustion Protégez les composantes éle...

Page 13: ...RTE 15 INSTALLATION DE LA PORTE PLANE 16 OPTIONS DE TUYAUTERIE 16 SYSTÈMES DE TUYAUTERIE FLEXIBLE 16 SYSTÈMES DE CONDUITS SOLIDES POUR LE PLANCHER 16 DÉCHARGE PAR LE BAS HORIZONTALE OU VERTICALE 17 PLAQUE D ADAPTATEUR FLEXIBLE 17 CONNEXION DE GAZ PROPANE 17 CONNEXIONS ÉLECTRIQUES 18 INSTALLATION DU THERMOSTAT 18 INSTRUCTIONS D UTILISATION 18 POUR METTRE HORS TENSION 19 SPÉCIFICATIONS MODÈLES Table...

Page 14: ...roite Toujours installer la fournaise sur un mur avec paroi extérieure NE PAS installer la fournaise près d une chambre à bascule de murs coulissants de portes ou autres projections qui pourraient compromettre l échappement de la fournaise Placez la fournaise vers le milieu du guide pour l installation d une seule fournaise L installation doit être accessible si une réparation est nécessaire pour ...

Page 15: ...sion d air de combustion Fixez au mur avec deux vis non fournies 15 L assemblage du conduit doit maintenir un chevauchement minimum de 1 1 4 po sur le tube d échappement et un minimum de 1 2 po du tube de combustion d air NE PAS excéder l épaisseur du mur 16 Fixez la fournaise au plancher avec deux vis à travers les pieds à l arrière du boitier Pour les appareils à la verticale maintenez la fourna...

Page 16: ...omplètement scellé 11 Fixez le pied de montage au plancher pour une installation horizontale Pour les unités verticales retirez les vis des pieds du boitier et repositionnez le pied pour une surface de montage verticale pour maintenir la fournaise en position 12 Fixez la porte et le conduit avec les 6 vis fournies bonne pression statique OPTIONS DE TUYAUTERIE DÉCHARGE MINIMUM REQUISE Modèles Zone ...

Page 17: ...hez les conduits flexibles de la fournaise à la plaque d adaptateur flexible et fixez le conduit en place sur les deux côtés 8 Des conduits additionnels peuvent être utilisés pour maintenir une bonne pression statique ou telle que désirée VÉRIFICATION DU FLUX D AIR Les appareils sont testés pour une augmentation de la température telle que spécifiée dans le plateau de classement Lorsque l installa...

Page 18: ...de la fournaise 2 Connectez le câble rouge au côté positif du bloc d alimentation 3 Connectez le câble noir à la mise à la terre du bloc d alimentation 4 Connectez le fil bleu marqué positif du thermostat au côté du fil du thermostat en utilisant un fil toronné de 22 18 GA 5 Connectez l autre fil bleu à la tête du thermostat en utilisant un fil toronné d un minimum de 22 18 GA ALIMENTATION ÉLECTRI...

Page 19: ...ve de fermeture automatique individuelle doivent être déconnectées du système de tuyau vers l approvisionnement en gaz durant le test de la pression du système aux tests de pression de plus de 1 2 po PSI Avant de connecter la fournaise le système de tuyaux doit être testé pour les fuites Le test doit maintenir la pression d air à au moins 6 po de mercure ou 3 PSI durant au moins 10 minutes Le syst...

Reviews: