9. Attach access door.

a. Snap hinge pin (

FIG

3-C) into clip (

FIG

3-D).

b. Slide cover (

FIG

3-E) onto hinge pin.

c. Slide hinge pin into cover, snapping into clip at same time (

FIG

3-D).

NOTE

: To remove hinge pin, support access cover and apply force to

corner of hinge pin.

10. Disconnect unit and its individual shut-off valve from gas supply

line during any pressure testing of system in excess of 1/2 PSIG
(3.4 kPa, 14˝ water column [W.C.]). 

DO NOT

set inlet pressure higher

than maximum indicated on rating plate of gas valve (13˝ W.C.).
Isolate unit from gas supply line by closing its individual manual
shutoff valve during any pressure testing 

1/2 psig.

WARNING

FIRE AND/OR EXPLOSION

• 

DO NOT

use matches, candles or other sources of ignition when

checking for gas leaks.

11. Turn on gas and check water heater and all connections for gas

leaks with leak detecting solution.

12. Fill water heater tank, check all connections for water leaks.

MIXING VALVE - (

FIG

9)

WARNING

SCALDING INJURY

Valve is not serviceable, it must be replaced.

Replacement by a Certified Service Technician only.

Tampering with valve will result in scalding injury. 

Tampering with valve will void warranty.

THIS VALVE IS A SAFETY COMPONENT AND MUST NOT BE REMOVED FOR ANY REASON
OTHER THAN REPLACEMENT. REMOVAL FOR REPLACEMENT BY A CERTIFIED SERVICE
TECHNICIAN ONLY

The water heater is equipped with a mixing

(moderating) valve which mixes cold water with higher temperature
water to moderate outlet water to approximately 130˚F. It is also
equipped with a higher temperature thermostat, raising the storage
water temperature.

PRESSURE-TEMPERATURE RELIEF VALVE - 

(

FIG

3-G)

WARNING

SCALDING INJURY

Valve is not serviceable, it must be replaced.

Tampering with valve will result in scalding injury. 

Tampering with valve will void warranty.

WARNING

EXPLOSION

• 

DO NOT

place a valve, plug or reducing coupling on outlet part of

pressure-temperature relief valve.

THIS VALVE IS A SAFETY COMPONENT AND MUST NOT BE REMOVED FOR ANY REASON
OTHER THAN REPLACEMENT.

This water heater is equipped with a

temperature and pressure relief valve that complies with the standard
for Relief Valves and Automatic Gas Shutoff Devices for Hot Water
Systems, ANSI Z21.22. 

If you use a discharge line, do not use a reducing coupling or other
restriction smaller than outlet of relief valve. Allow complete drainage
of both valve and line.

FOR REPLACEMENT PARTS:
• 

DO NOT

install anything less than a combination temperature-pressure

relief valve certified by a nationally recognized testing laboratory that
maintains periodic inspection of product of listed equipment or
materials, as meeting requirements for Relief Valves and Automatic
Gas Shutoff Devices for Hot Water Supply Systems, ANSI Z21.22.
Valve must have a maximum set pressure not to exceed 150 psi.

• Install valve into opening provided and marked for this purpose on

water heater.

• Installation must conform with local codes or in the absence of local

codes, American National Standard for Recreational Vehicles, ANSI
A119.2/NFPA 50IC.

• For an external electrical source, ground this unit in accordance with

National Electrical Code ANSI/NFPA70.

Your 

ATWOOD WATER HEATER

is now ready for operation. Continue to

HOW TO OPERATE YOUR WATER HEATER.

CONSUMER SAFETY WARNINGS

WARNING

EXPLOSION OR FIRE

• DO NOT

store or use gasoline or other flammable vapors and liquids in

the vicinity of this or any other appliance.

Should overheating occur, or gas supply fail to shut off, turn gas

OFF

at the LP tank. On 

ELECTRONIC IGNITION MODEL

turn operating

switch to 

OFF

position and remove red wire from left hand terminal

of ECO switch or turn gas 

OFF

at the LP tank.

Use with LP gas only.

Shut off gas appliances when refueling.

Turn gas 

OFF

at the LP tank when vehicle is in motion. This disables

all gas appliances. Gas appliances must never be operated while
vehicle is in motion. Unpredictable wind currents may be created
which could cause flame reversal in the burner tube, which could
result in fire damage. The thermal cut off fuse could also be
unnecessarily activated resulting in a complete shutdown of the
water heater requiring replacement of the thermal cut off. See
maintenance of electronic ignition water heaters for further
explanation of the thermal cut off.

LP tanks must be filled by a qualified gas supplier only.

HOW TO OPERATE YOUR WATER HEATER

CAUTION

FIRE

Do not smoke or have any flame near an open faucet.

If water heater has not been used for more than two weeks, hydrogen
gas may form in water line. Under these conditions to reduce the risk
of injury, open hot water faucet for several minutes at kitchen sink
before you use any electrical appliance connected to hot water system.

If hydrogen gas is present, you will probably hear sounds like air
escaping through the pipe as water begins to flow.

WARNING

SCALDING INJURY

• Do not tamper with orifice or mixing valve.

CAUTION

PRODUCT FAILURE

• Do not operate without water in tank.

3

14

INTENTIONALLY LEFT BLANK

Summary of Contents for XT G16EXT

Page 1: ...du brûleur c nettoyage ou réglage du tube du brûleur d nettoyage ou réglage du conduit e nettoyage ou réglage de la veilleuse et du thermocouple f réglage de la soupape de décharge de type pression température g remplacement du dispositif de coupure thermique 4 Dans l éventualité d une réclamation de garantie l acheteur doit contacter à l avance soit un Centre de service Atwood agréé soit le Servi...

Page 2: ...ground wire from electrical service to 3 green ground lead in junction box 3 CAUTION PRODUCT DAMAGE When using Romex with a bare earth ground take care to position ground wire so it does not contact the heating element terminals When a cord and plug connection to the power supply are used on water heater power cord must be UL listed as suitable for damp locations hard or extra hard usage It must b...

Page 3: ...RTS DO NOT install anything less than a combination temperature pressure relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of product of listed equipment or materials as meeting requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems ANSI Z21 22 Valve must have a maximum set pressure not to exceed 150 psi I...

Page 4: ...portée à bord soit avec de l eau sous pression externe Continuer le processus de rinçage pendant environ cinq minutes ceci permet à l eau claire de remuer l eau stagnante du fond du réservoir et de pousser les dépôts par l orifice d évacuation 4 Replacer le bouchon de vidange et la soupape de décharge de type pression température 5 Remplir le réservoir avec de l eau claire ne contenant pas de souf...

Page 5: ...r l obturateur d air FIG 4 B le long du tube du brûleur b Introduire une brosse métallique flexible à l intérieur du tube du brûleur FIG 4 D jusqu à ce qu elle ressorte par l autre extrémité du tube c Nettoyer le brûleur à l aide d un aspirateur à l endroit où il s insère dans le tube de combustion d Remettre l obturateur d air dans sa position d origine et replacer la vis e The orifice burner tub...

Page 6: ...réducteur ou toute autre restriction qui soit inférieure en diamètre à la sortie de la soupape de décharge Laisser la soupape et la conduite s écouler complètement PIÈCES DE RECHANGE Installer AU MINIMUM une soupape de décharge combinée de type température pression homologuée par un laboratoire de test reconnu au niveau national qui inspecte régulièrement les produits d équipement ou de matériaux ...

Page 7: ...blanc 2 c Brancher le fil de masse de l alimentation électrique sur le fil de masse vert 3 du boîtier de dérivation 3 ATTENTION ENDOMMAGEMENT DU PRODUIT Lorsqu on utilise Romex avec une mise à la terre nue faire attention de placer le fil de mise à la terre de manière à ce qu il n entre pas en contact avec les bornes de l élément de chauffe Lorsqu on utilise une connexion avec fil et fiche pour al...

Page 8: ... d entretien qualifié le plus proche pour effectuer toute réparation S il est impossible de joindre un fournisseur en gaz ou un technicien d entretien qualifié contacter la caserne de pompiers la plus proche NE PAS ouvrir l alimentation en gaz avant que la ou les fuites soient réparées ENGLISH FRANÇAIS et Canada Installation Fonctionnement Entretien En vigueur à partir du 09 04 09 NUMÉRO DE BROCHU...

Reviews: