CRAFT LINE INTERFACE (CLI)
4-4
ChromaFlex Chassis – Operation Manual
ATX Confidential & Proprietary
Example
#1:
ChromaFlex[slot-7]
>status
Slot
7
(CCTX)
ModuleTemp: (deg C)
+50.3
LaserTemp: (deg. C)
[1] -14.8 [2] -14.8 [3] -14.7 [4] -14.8
LaserPowerMw:
(Mw)
[1] +0.0 [2] +0.0 [3] +0.0 [4] +0.0
LaserPowerdBm:
(dBm)
[1] -19.1 [2] -19.2 [3] -19.2 [4] -19.8
LaserRf:
(dB)
[1] +0.8 [2] +0.8 [3] +0.8 [4] +0.8
Attenuation:
(dB)
+0.8
GainOffset:
(steps)
+1
GainControl:
MGC
alarm:
displays the alarm status of the chassis and the selected slot plug-in module.
Example
#1:
ChromaFlex[slot-7]
>alarm
System
PowerAlarm:
Normal
FanAlarm:
Normal
Slot
7
(CCTX)
LaserTempAlarm:
[1] MajorLoLo [2] MajorLoLo [3] MajorLoLo [4] MajorLoLo
LaserPowerAlarm:
[1] MajorLoLo [2] MajorLoLo [3] MajorLoLo [4] MajorLoLo
LaserRfAlarm:
[1] MajorLoLo [2] MajorLoLo [3] MajorLoLo [4] MajorLoLo
ModuleTempAlarm:
MinorLo
DownloadStatus:
displays the status of the current or previous download.
Example #1: This example shows the previous download was completed successfully.
ChromaFlex[slot-1] >downloadstatus
Successful