CRAFT LINE INTERFACE (CLI)
4-8
ChromaFlex Chassis – Operation Manual
ATX Confidential & Proprietary
The CCTX consumes two physical slot spaces, the lower number slot is defined as the true physical slot for the CLI slot
menu, the higher adjacent slot number is defined as a virtual slot. The CLI menu will not communicate with a virtual slot.
Example #1: The CCTX module is plugged into slot 1 and occupies slot 1 and slot 2. Slot 1 is the physical and slot 2 is the
virtual slot.
ChromaFlex[slot-1] >slot
Slot 1 – CCTX
Slot 2 – CCTX
Slot
3
–
AGC-EDFA
Slot 4 – Empty
Slot 5 – Empty
Slot 6 – Empty
Slot 7 – Empty
Slot 8 – Empty
Selecting the physical slot (slot 1), displays the module information.
ChromaFlex[slot-1] >slot 1
Slot 1 (
CCT4
) selected
Selecting the virtual slot (slot 2), results in no module information being available.
ChromaFlex[slot-1] >slot 2
Slot 2 (
Empty
) selected
ModuleTemp:
displays the module temperature reading in Centigrade.
Example #1: In this example, the module in slot 1 reports its module temperature reading as 21.4
Centigrade.
ChromaFlex
[slot-1]
>ModuleTemp
+21.4
deg
C
LaserTemp:
displays the laser temperature reading in Centigrade.
Example #1: In this example, the module in slot 1 reports its laser temperature reading on Laser channel 1
ChromaFlex [slot-1] >LaserTemp 1
+23.0
deg
C
LaserPowerMw:
displays the laser power reading in mW.
Example #1: In this example, the module in slot 1 reports its laser power reading on Laser 1.
ChromaFlex[slot-1]
>LaserPowermW
1
+0.0
mW
LaserPowerDbm:
displays the laser power reading in dBm.
Example #1: In this example, the module in slot 1 reports its laser power reading on Laser 1.
ChromaFlex[slot-1]
>LaserPowerDbm
1
+0.0
dBm
LaserRf
: displays the RF reading in dB.
CHAPTER 4: