CRAFT LINE INTERFACE (CLI)
ChromaFlex Chassis – Operation Manual
4-9
ATX Confi dential & Proprietary
Example #1: In this example, the module in slot 1 reports its RF reading on channel 1.
ChromaFlex[slot-1]
>LaserRf
1
+0.0
dB
Wavelength:
displays the laser wavelength in nanometer.
Example #1: In this example, the module in slot 1 reports its laser #1 wavelength.
ChromaFlex[slot-1]
>WaveLength
1
1546.12
nm
Attenuation:
displays the RF attenuation setting in dB.
Example #1: In this example, the module in slot 1 reports its RF attenuation setting.
ChromaFlex [slot-1] >attenuation 1
+4.9
dB
GainOffset:
displays the gain offset setting in steps.
Example #1: In this example, the module in slot 1 reports its gain offset setting.
ChromaFlex [slot-1] >gainoffset 1
0
steps
Modifi cation
: this command supports modifi cation.
Example #1: In this example, the interface #1 of the slot 7 module’s GainOffset is confi gured
with 2.
ChromaFlex [slot-7] >GainOffset 1 modify 2
Request
sent
ChromaFlex[slot-7]
>GainOffset
1
+2
steps
NOTE: The response of a modifi cation request may either be “Request sent” or “Successful”; in
either case, the user shall retrieve the value to confi rm the new value. You may need to wait for a
few seconds or retrieve a couple times to acquire the new value.
GainControl:
displays the gain control mode setting.
Example #1: In this example, the module in slot 1 reports its gain control mode.
ChromaFlex
[slot-1]
>gaincontrol
MGC
Modifi cation:
this command supports modifi cation.
Example #1: In this example, the interface #1 of the slot 7 module’s GainControl is confi gured with MGC
mode.
CHAPTER 4: