CRAFT LINE INTERFACE (CLI)
ChromaFlex Chassis – Operation Manual
4-13
ATX Confidential & Proprietary
Example #1: In this example, the module in slot 1 reports the alarm status of optical output power as
“MajorLoLo” (e.g. Major alarm with power reading below the low low threshold).
ChromaFlex [slot-1] >OPoutPowerAlarm 1
MajorLoLo
4.1.3.3 EDFA / AGC-EDFA
The commands in this section are EDFA or AGC-EDFA specific.
ModuleTemp:
displays the module temperature reading in Centigrade.
Example #1: In this example, the module in slot 1 reports its module temperature reading as 21.4
Centigrade.
ChromaFlex
[slot-1]
>ModuleTemp
+21.4
deg
C
OPinPower:
displays the optical input power reading in dBm.
Example #1: In this example, the module in slot 1 reports its optical input power reading.
ChromaFlex [slot-1] >OPinPower 1
+0.0
dBm
OPoutPower:
displays the optical output power reading in dBm.
Example #1: In this example, the module in slot 1 reports its optical output power reading.
ChromaFlex [slot-1] >OPoutPower 1
+0.0
dBm
Gain:
displays the gain reading in dB for an AGC type EDFA. This is configurable for EDFA with AGC.
Example #1: In this example, the module in slot 1 reports its gain reading.
ChromaFlex [slot-1] >gain 1
20
dB
OPinPowerAlarm:
displays the alarm status of optical input power.
Example #1: In this example, the module in slot 1 reports the alarm status of optical input power as
“MajorLoLo” (e.g. Major alarm with power reading below the low low threshold).
ChromaFlex [slot-1] >OPinPowerAlarm 1
MajorLoLo
OPoutPowerAlarm:
displays the alarm status of optical output power for a constant output power EDFA type or the alarm
status of gain for a constant gain “AGC” EDFA type.
CHAPTER 4: